Otsuka Electronics Analytical & Optical Metrology Equipment

Otsuka Electronics (Japan) particle size and zeta-potential analyzers (ELSZneo, ELSZ-2000ZS, nanoSAQLA, DLS-8000), optical film thickness monitors and ellipsometers (OPTM, FE-300, FE-5000, SF-3), MCPD spectrometers, RETS/LCF inspectors, and MINUK 3D wave field microscope.

Particle Size and Zeta-Potential Analyzers ELSZneo & ELSZ-2000ZS

ELSZneo and legacy ELSZ-2000ZS analyzers measure particle size from 0.6 nm to 10 um and zeta potential across 0 to 90 C. Systems handle suspensions up to 40% concentration and flat plates in high-salt buffers. Service spares include flow cells, flat cells, laser module, and APD detector.

  • Particle size: 0.6 nm to 10 um
  • Concentration: 0.00001% to 40%
  • Molecular weight: 340 to 2 x 10^7
  • Spares: cells, laser, APD detector

Light-Scattering Analyzers nanoSAQLA, DLS-8000, and PP-1000

nanoSAQLA, DLS-8000, and PP-1000 systems analyze nanoparticles from 0.6 nm, polymers, and 1.3–175 um spherulites. AS50 autosampler expands nanoSAQLA throughput from 5 to 50 samples, while DLS-8000 uses a 4,096-channel correlator. Spares cover 20 uL micro cells, 660/785 nm lasers, and PMT.

  • nanoSAQLA: 5 or 50 samples (AS50)
  • DLS-8000: 5 to 160 deg, 4096-ch
  • PP-1000: 785 nm laser, 1.3–175 um
  • Spares: micro cells, lasers, PMT

Optical Film Thickness Monitors OPTM, FE-300, FE-5000, and SF-3

OPTM, FE-300, FE-3, FE-5000, SF-3, and Line-Scan instruments measure films and Si wafers from 0.1 nm to 1.5 mm. OPTM resolves up to 50 layers with 0.1 nm repeatability and a 3 um spot, while SF-3 monitors CMP at 5 kHz. Spares include Y optical fibers, white LED, halogen, and xenon lamps.

  • OPTM: 230–1600 nm, up to 50 layers
  • FE-5000: ellipsometry 0.1 nm–1 um
  • SF-3 / Line-Scan: 5 kHz, 1 mm res
  • Spares: Y-fibers, LED/Xe/halogen lamps

Array Spectrometers MCPD-9800/6800, LE-5400, and HM/FM, GP Photometers

MCPD-9800/6800 array spectrometers, LE-5400, HM/FM hemispheres, and GP goniophotometers cover 220–1600 nm spectra and luminous flux. Cooled CCD, PDA, and InGaAs detectors (512/1024 ch) run down to 2–5 ms exposure via USB/LAN. Spares cover quartz scramble fibers and flux standard lamps.

  • MCPD-9800/6800: 220–1600 nm, CCD/InGaAs
  • LE-5400: 2 ms min exposure, LED bin
  • HM/FM & GP: spheres 250–3000 mm
  • Spares: quartz fibers, standard lamps

LCD Cell Gap and Retardation Systems RETS, RETS-100nx, RE-200, and LCF

RETS, RETS-100nx, RE-200, and LCF systems measure 0.1–600 um LCD cell gaps, retardation up to 60,000 nm, and RGB/ITO filters up to 3,000 mm glass. Glan-Thompson optics (10^-5) hit ±0.005 um repeatability. Spares cover 100 W halogen lamps, polarization prisms, and CCD modules.

  • RETS / 100nx: gap 0.1–600 um (±0.005)
  • Retardation: 0–60,000 nm, RE-200 <0.1 s
  • LCF: glass 50–3,000 mm, RGB/ITO/PI
  • Spares: Glan-Thompson prism, 100 W lamp

Three-Dimensional Optical Wave Field Microscope MINUK

MINUK 3D wave field microscope images films, waveguides, glass defects, and living cells without physical focusing. A single capture covers 700 x 700 um and ±700 um depth at 488 nm lateral and 10 nm Z resolution. Spares include the 638 nm laser module, sample holders, and XY stages.

  • Resolution: 488 nm (X,Y) / 10 nm (Z)
  • Field & depth: 700 x 700 um, ±700 um
  • Laser: 638 nm, <= 0.39 mW, Class 1
  • Spares: laser unit, sample holder, XY stage

Selecting Otsuka Electronics Analyzers and Optical Metrology Systems

For nanoparticle sizing, zeta potential, and concentrated suspensions up to 40%, laboratories select ELSZneo or the 5/50-sample nanoSAQLA platform; polymer research requiring angular scattering (5 to 160 deg) and radius of gyration uses DLS-8000 or PP-1000.

Semiconductor, FPD, and optical coating lines deploy OPTM and FE-300 thickness monitors, the FE-5000 spectrum ellipsometer, SF-3 Si wafer monitor, Line-Scan Thickness Monitor, MCPD-9800/6800 spectrometers, RETS/LCF inspection tools, and the MINUK 3D microscope.

Configuration Options, Measurement Cells, and Optical Accessories

Systems are configured to sample chemistry, film stack count, and substrate size (up to 3,000 x 3,000 mm on LCF or 200/300 mm wafers on OPTM) with optional flat-surface cells, 20 uL micro cells, AS50 autosampler, Glan-Thompson polarization stages, and quartz optical fibers.

Otsuka Electronics and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Otsuka Electronics and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.