Testo flue gas analyzers and electrochemical sensors — selection and sourcing
Industrial and portable Testo flue gas analyzers (testo 350, testo 340, testo 330, testo 300), precalibrated O2, CO, NO and SO2 sensors, sampling probes and sample gas pumps. Configuration and quotation by application.
Electrochemical O2 measuring cells
Precalibrated O2 sensor 0393 0000 measures 0 to 25 vol.% with 0.01 vol.% resolution, ±0.2 vol.% accuracy and a response time below 20 s (t95) for testo 340 and testo 350 analyzers. It sets the oxygen reference for flue gas calculations. Longlife 0393 0012 and 0390 0070 also fit.
- Part numbers: 0393 0000, 0393 0012, 0390 0070
- Range: 0 to 25 vol.%, resolution 0.01 vol.%
- Accuracy ±0.2 vol.%, response t95 < 20 s
- 15-minute acclimatization after replacement
H2-compensated CO electrochemical sensors
Replacement CO cell 0393 0104 (0 to 10,000 ppm, 1 ppm resolution) and COlow cell 0393 0102 (0 to 500 ppm, 0.1 ppm resolution) feature integrated H2 compensation. Both cells deliver t90 response under 40 s on boilers and engines. Single-slot x40 dilution extends CO measurement up to 400,000 ppm.
- Spare cells: 0393 0104 (CO) and 0393 0102 (COlow)
- Retrofit kits: 0554 2104 and 0554 2102
- H2-compensated cell, response time t90 < 40 s
- Up to 400,000 ppm with x40 dilution option
NO, NOlow and NO2 electrochemical cells
Separate NO and NO2 channels ensure accurate total NOx readings using NO 0393 0150 (0 to 4,000 ppm), NOlow 0393 0152 (0 to 300 ppm) and NO2 0393 0200 (0 to 500 ppm). Maritime analyzers use NO cell 0393 0154 with spare filter 0554 3372. Response times are under 30 s for NO and 40 s for NO2.
- Cells: 0393 0150 (NO), 0393 0152 (NOlow), 0393 0200 (NO2)
- Maritime NO cell 0393 0154, spare filter 0554 3372
- Retrofit kits: 0554 2150, 0554 2152, 0554 2200
- Response t90 < 30 s (NO) and < 40 s (NO2)
SO2 and H2S electrochemical sensors
Heavy fuel, coal and biogas emission measurements rely on SO2 0393 0250 (0 to 5,000 ppm, 1 ppm resolution, t90 < 30 s), SO2low 0393 0251 and H2S 0393 0350 (0 to 300 ppm, 0.1 ppm resolution, t90 < 35 s). Single-slot x40 dilution extends SO2 range up to 200,000 ppm.
- Cells: 0393 0250 (SO2), 0393 0251 (SO2low), 0393 0350 (H2S)
- Retrofit kits: 0554 2250 (SO2) and 0554 2350 (H2S)
- SO2 accuracy ±5 ppm (0–99 ppm) / ±5% (100–1999 ppm)
- Up to 200,000 ppm SO2 with x40 dilution
Testo 350 modular emission analyzers
The modular testo 350 emission analyzer (0632 3510 / 0632 3511) accommodates up to 6 gas sensors, integrated Peltier gas preparation and up to x40 single-slot dilution for high industrial concentrations. Optional slots cover IR CO2 and CxHy 0393 0300. Analog output 0554 3149 adds 4–20 mA.
- Control unit 0632 3510 and analyzer box 0632 3511
- Up to 6 slots: O2, CO, NO, NO2, SO2, H2S, CxHy, CO2-IR
- Integrated Peltier cooler and 250,000-reading memory
- 6-channel 4–20 mA analog output box 0554 3149
Testo 340, testo 330 and testo 300 analyzers
The 4-channel testo 340 flue gas analyzer handles burner and boiler commissioning with a base O2 sensor, 3 selectable slots and x5 dilution extending CO range up to 50,000 ppm. Built-in differential pressure enables flow calculation. Commercial heating lines include testo 300 and testo 330.
- testo 340 (0632 3340): O2 + 3 customizable slots
- x5 dilution extends CO range up to 50,000 ppm
- Built-in differential pressure and flow sensors
- Commercial burner models: testo 300 and testo 330
Flue gas probes, Pitot tubes and filters
Modular flue gas probes cover temperatures up to 500 °C (0600 9766, 0600 9767) and 1000 °C (0600 8764, 0600 8765, 0600 8766 with pre-filter), plus engine probe 0600 7555. Gas paths rely on particle filters 0554 3385, sintered filters 0554 3381 and Pitot tubes 0635 2145 and 0635 2345.
- 500 °C probes: 0600 9766 (700 mm), 0600 9767 (335 mm)
- 1000 °C probes: 0600 8764, 0600 8766; engine 0600 7555
- Filters: handle 0554 3385 (20 pcs), sintered 0554 3381
- Pitot tubes: 0635 2145 (350 mm), 0635 2345 (1,000 mm)
Sample pumps, diaphragms and condensate traps
Controlled sample gas flow of 1 l/min (±0.1 l/min) in testo 350 is maintained by main pump 0239 0031 (diaphragm 0193 0049) and rinsing/dilution pump 0239 0014 (diaphragm 0193 0072). Condensate removal up to 70 °Ctd dew point uses motor 0238 0001 and tube cartridge 0440 0013.
- Main pump 0239 0031 (1 l/min), diaphragm 0193 0049
- Dilution/rinsing pump 0239 0014, diaphragm 0193 0072
- Condensate motor 0238 0001 and cartridge 0440 0013
- Max dust load 20 g/m3, max humidity 70 °Ctd
Selecting a Testo analyzer for industrial emissions
For routine commissioning and service of industrial burners and boilers, the compact 4-channel testo 340 combines a standard O2 cell with three customizable slots (CO, NO, NO2, SO2) and x5 dilution up to 50,000 ppm CO.
For heavy-duty engine, turbine and compliance monitoring, the modular testo 350 system (0632 3510 / 0632 3511) provides up to 6 sensor slots, an integrated Peltier gas cooler, single-slot dilution up to x40 and 4–20 mA analog output module 0554 3149.
Configuring probes, filters and spare sensor cells
Depending on stack temperature, systems are configured with 500 °C probes (0600 9766, 0600 9767) or 1000 °C probes (0600 8764, 0600 8766), Pitot tubes (0635 2145, 0635 2345) and handle or sintered filters (0554 3385, 0554 3381).
Precalibrated 0393 series electrochemical cells (O2, H2-compensated CO, NO, NO2, SO2, H2S) and 0554 retrofit kits are matched to the instrument serial number and active slot layout.
Testo and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Testo and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for City Technology
- Equipment and parts for Alphasense
- Equipment and parts for Semeatech
- Equipment and parts for RIKEN KEIKI
Documents and sources
- Testo SE & Co. KGaA official portal — industrial measuring technology
- testo 350 Instruction Manual — sensor specifications and spare part numbers
- testo 350 Maritime Instruction Manual — NO sensor 0393 0154, pumps and diaphragms
- Testo 340 and testo 350 boiler and burner application guide (CN)
- Testo whitepaper on combustion efficiency and emissions for testo 340 and testo 350