Hexatronic Micro Cables, Microducts and Closures

Swedish Hexatronic Group makes Viper micro cables, Stingray air blown fiber, microducts, dome closures, InOne powered fiber and submarine cables for telecom networks.

Viper Micro Cables for Air-Blown Installation

The Hexatronic Viper TOL4019028+AH micro cable holds up to 432 G.657.A1 fibers in polyamide tubes and is blown into microducts with an inner diameter of 8 to 12 mm. It operates from -45 to +70 °C with a bend radius of 70 mm or more. Super Slim with 200 µm fibers holds up to 864 fibers.

  • Up to 432 G.657.A1 fibers
  • TOL4019028+AH: -45 to +70 °C
  • Bend radius 70 mm or more
  • Blowing 2000 m: 8-10 mm duct, cable up to 6.7 mm

Viper Core Transport-Grade Micro Cables

Viper Core TOL4019110+C targets transport networks and data center interconnects with 288 to 864 fibers and maximum attenuation of 0.20 dB/km at 1550 nm. At a 40-75% duct fill ratio it blows 2000 m per IEC 60794 and up to 3000 m on a straight path. Supplied lengths are 2, 4 and 8 km.

  • 288 to 864 G.657.A1 fibers
  • Max 0.20 dB/km at 1550 nm
  • Up to 3000 m on a straight path
  • Supplied lengths 2, 4 and 8 km

Stingray Air Blown Fiber and LTT1792040 Blowing Tool

Stingray KRPM258+C1 units with 2, 4, 6, 8 or 12 G.657.A1 fibers blow 1000 m into 3.5-4 mm ducts and ship in 1000 to 6000 m lengths. The handheld LTT1792040 tool feeds fiber at up to 150 m/min and needs an air flow of 80 l/min at a nominal pressure of 8 bar for optimal blowing.

  • Units with 2 to 12 G.657.A1 fibers
  • Blowing 1000 m in 3.5-4 mm ducts
  • Tool speed up to 150 m/min
  • Air 80 l/min at 8 bar

Microducts and Connectors for Direct Burial

Hexatronic MPB30255+M assemblies bundle 2, 4 or 7 HDPE microducts of 20/15 mm with a grooved low-friction bore for direct burial. MPB30601+ connectors and end stops for 3 to 20 mm ducts are IP68 rated, work below 15 bar, and internal steel teeth hold the duct.

  • 2, 4 or 7 ducts of 20/15 mm
  • HDPE ducts and outer jacket
  • Connectors for 3-20 mm ducts, IP68
  • Working pressure below 15 bar

SHDC and LHDC Dome Closures

Hexatronic dome closures come in four sizes: SHDC-AA for 144 (288) splices, SHDC-AB and LHDC-AA for 288 (576), and LHDC-AB for 672 (1344). The IP68 base and dome use a clamp and O-ring system, and LHDC mechanical compression port seals take 5 to 21 mm cables without heat shrink.

  • LHDC-AB: 672 (1344) splices
  • IP68 dome with clamp and O-ring
  • LHDC cable diameter 5-21 mm
  • Port seals without heat shrink

InOne Powered Fiber System

The InOne TOL4079028+ micro hybrid cable carries up to 24 fibers and 4 to 8 copper wires of 0.75 to 1.5 mm² and is blown into ducts down to 8 mm. Fed with 110 Vdc, terminals with DC/DC units deliver 48 Vdc: 150 W at 700 m and 110 W at 1000 m. The A-HAN E10s node gives 150 W in IP65.

  • Up to 24 fibers, 4 to 8 copper wires
  • 150 W at 700 m, 110 W at 1000 m
  • A-HAN E10s node: 150 W, IP65
  • Hybrid ODF panel: 120 Vdc, 10 A

FTTA Cable Assemblies for Radio Sites

HRPM25412+ trunk assemblies link BBU and RRU units with RDC and LC connectors for 6 and 12 RRU systems and operate from -40 to +70 °C. HRPM254123+ LCD jumpers are IP67 rated, HRPM254110+ hybrid assemblies carry 4 or 6 mm² power cords, and the NTM5041136+ box terminates up to 24 RRU units.

  • RDC-LC trunks for 6 and 12 RRU
  • LCD to LCD jumpers, IP67
  • Hybrid assemblies with 4 or 6 mm² cords
  • NTM5041136+ box for 24 RRU

Submarine and Underwater Fiber Cables

The 10 ton SA submarine cable with 12 to 192 fibers is rated for a water depth of 3000 m at a 22 mm diameter, with fibers in a hermetically sealed stainless tube under one layer of 14 galvanized steel wires. The TOL4043005+C river cable is rated to 200 m depth and 10 km lengths.

  • 10 ton SA: water depth 3000 m
  • 22 mm diameter, 12 to 192 fibers
  • River cable: depth down to 200 m
  • Max continuous length 10 km

Selecting a Hexatronic Cabling System for the Route

Hexatronic builds a duct-and-cable system: 20/15 mm HDPE microduct assemblies with 2, 4 or 7 ducts for direct burial, Viper micro cables with up to 432 fibers for 8-12 mm ducts, Viper Core with up to 864 fibers for transport routes, and Stingray air blown fiber with 2 to 12 fibers for FTTH drops.

Routes are joined in IP68 SHDC and LHDC dome closures with up to 672 (1344) splices, remote cameras and small cells are fed through InOne hybrid cables, radio masts use FTTA assemblies, and water crossings use river and submarine cables.

Production and Outgoing Inspection

Hexatronic Group is headquartered in Gothenburg, Sweden. Micro cables, air blown cables, ducts, submarine and powered fiber cables are produced at the Hudiksvall plant, opened in 1967; Hexatronic took over this cable business from Ericsson in 2013.

According to the plant, a metal ball is blown through every duct and every fiber in each cable is OTDR tested before shipment.

Hexatronic and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Hexatronic and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.