CONTROL VALVES AND PROCESS AUTOMATION

SAMSON equipment

Specify a SAMSON control valve, pneumatic diaphragm actuator, digital positioner or self-operated regulator matched to your process media, pressure drop and plant design.

SAMSON control valves and automation systems

Choose a process category. Attach an equipment data sheet, nameplate photo or engineering specification to make the enquiry precise.

Globe and angle control valves 3241 and 3251

Globe and angle control valves Type 3241, 3251, 3244 and 3321 control flow rates of liquids, gases and steam in industrial plants. The modular design accommodates noise-reducing trims, TA-Luft bellows seals and exchangeable seats matched to the required flow coefficient Kvs.

Specify pipe size DN, pressure rating PN, differential pressure, fluid medium and operating temperature.

Pneumatic diaphragm actuators 3271 and 3277

Multi-spring diaphragm actuators Series 3271 and 3277 generate positioning force for linear control valves. The actuators provide fail-close or fail-open safety functions via internal springs upon loss of pneumatic supply air.

Order data: diaphragm area (120–2800 cm²), stroke length, spring range and fail-safe direction.

Electric linear actuators 3374

Electric actuators Series 3374 with thrust forces from 500 to 2500 N operate in industrial plants and district heating networks. An optional mechanical spring return ensures rapid fail-safe valve positioning within 2 to 8 seconds on power failure.

Specify thrust force, power supply (230V / 24V), control signal (4–20mA / 0–10V) and fail-safe spring requirement.

Digital electropneumatic positioners 3730

Smart positioners SAMSON 3730 provide precise stem positioning via analogue current loops or fieldbus communication. The integrated EXPERTplus firmware conducts diagnostic tests on packing friction, diaphragm health and partial stroke testing (PST).

State model 3730-X, communication protocol (HART, Profibus, FF), hazardous area rating Ex and limit switches.

Self-operated pressure regulators 41-23 and 41-73

Autonomous regulators Type 41-23 (pressure reducing) and Type 41-73 (excess pressure) maintain set pressures for steam, gases and liquids without auxiliary power. A pressure-balanced plug ensures stable setpoints regardless of inlet pressure fluctuations.

Specify setpoint range (bar), pipe size DN, pressure class PN, fluid medium and steam temperature.

Self-operated temperature regulators Type 1, 4, 8, 9

Self-operated temperature regulators control heating and cooling processes in boilers, heat exchangers and storage tanks. A thermostat connected by capillary tubing converts fluid thermal expansion directly into valve actuation force.

Specify temperature control range (°C), capillary length (2–15 m) and valve nominal diameter.

Heating and district heating controllers TROVIS 5576 and 5578

Electronic controllers TROVIS regulate heat distribution in substations and heating plants according to weather compensation curves. Onboard Modbus RTU and Ethernet communication interfaces enable seamless integration into building automation SCADA systems.

Specify number of heating/DHW circuits, communication interface and required Pt 1000 sensor set.

Specialized process valves of SAMSON Group companies

Group subsidiaries manufacture specialized flow control equipment for extreme conditions: Pfeiffer PTFE/PFA lined valves for corrosive chemicals, SED aseptic diaphragm valves for pharmaceuticals, Vetec rotary plug valves and Starline forged ball valves.

State subsidiary brand (Pfeiffer, SED, Vetec, Starline), valve category, fluid medium and connection standard.

Control valve sizing inputs

Process fluid, design flow rate, operating temperature, upstream and downstream pressures, required flow coefficient Kvs and actuation signal.

Components for installed equipment

Valve type, pipe size DN, pressure class PN, unique manufacturing identifier (Order No. or Var.-ID) and required spare items: diaphragms, seat rings, plugs or packing kits.

Identify valve model and execution details

SAMSON manufactures modular control valves; globe valve Series 3241, 3251 and 3321 differ in pressure ratings, body patterns and metallurgical specifications. To specify a replacement, copy the valve type, pipe size DN, pressure class PN and unique order number (Order No.

-ID) from the metal nameplate. A series designation alone leaves dozens of trim and packing configurations open. If the nameplate is painted over, provide clear photographs of the installed assembly showing port dimensions and actuator mounting.

Flow coefficient Kvs calculation and trim sizing

To size a control valve for a new process line, provide the fluid medium (steam, water, gas, hydrocarbons), density, operating and peak flow rates, and inlet/outlet pressures. These parameters determine the required flow coefficient Kvs, preventing cavitation, flashing and critical chokepoints.

SAMSON modular valve engineering allows seat rings and plugs to be replaced without removing the body from the pipeline, adapting installed assets to modified plant throughput.

Diaphragm actuator selection and thrust matching

Pneumatic actuators Series 3271 and 3277 are sized according to required closing thrust and valve travel. 0 bar). For plant safety configurations, define the required fail-safe action upon air failure: fail-close (FA / air-to-open) or fail-open (FE / air-to-close) powered by internal spring packs.

Electropneumatic positioners and fieldbus protocols

Digital positioners SAMSON 3730 ensure accurate valve stem alignment across linear and rotary applications. Specify the required communication protocol: standard analogue 4–20 mA current loop, HART digital layer (Type 3730-3), Profibus-PA (Type 3730-4) or Foundation Fieldbus (Type 3730-5).

For hazardous process environments, state whether intrinsic safety Ex ia or explosion-proof enclosure Ex d is required by your site classification.

Self-operated pressure regulators on steam service

Self-operated regulators Type 41-23 (pressure reducing) and Type 41-73 (excess pressure) function using medium line energy without external utilities.

On saturated or superheated steam service above 150 °C, an impulse condensation chamber must be fitted between the steam pipe and diaphragm actuator. The water seal prevents thermal degradation of elastomer diaphragms. Specify pressure setpoint range, steam temperature and capacity.

Self-operated temperature regulators and sensors

Temperature regulators Type 1, 4, 8, 9 and 2114 control heating and cooling loops in calorifiers, heat exchangers and pasteurisers. A sensor bulb connected via capillary tubing transmits fluid thermal expansion to the valve plug.

When ordering, state temperature setpoint range in Celsius, capillary length (2, 3, 5 m or extended up to 15 m) and thermowell material. If damaged, sensor thermostats are replaced as pre-calibrated hermetic modules.

TROVIS heating and HVAC automation controllers

Electronic microprocessor controllers TROVIS 5576 and 5578 regulate heat distribution in district heating substations and boiler houses using weather compensation curves.

Specify the number of heating and domestic hot water (DHW) circuits, communication bus interfaces (RS-485 Modbus RTU, Ethernet) and Pt 1000 temperature sensor assignments. When replacing equipment, provide installed firmware versions to retain circulation routines.

Pfeiffer PTFE and PFA lined valves for corrosive media

Valves produced by Group company Pfeiffer Chemiearmaturen feature monolithic fluoropolymer linings in PTFE and PFA, delivering superior chemical resistance against concentrated acids, chlorine, alkalis and aggressive solvents.

The ductile iron outer shell absorbs pipeline mechanical stresses while the fluoropolymer isolates the process medium. State exact chemical composition, concentration, operating temperature and allowable differential pressure.

SED Flow Control aseptic diaphragm valves

4435 (316L). 4 µm to eliminate bacterial adhesion and ensure validated CIP/SIP sanitisation cycles. State pipe connection standard (Tri-Clamp, orbital weld ends to DIN/ASME BPE) and diaphragm material (EPDM or PTFE/EPDM backed).

Configuration agreement and supply terms

Confirm the scope of supply: complete control assemblies with actuators and positioners, replacement seal kits, or standalone instrumentation modules. State exact nameplate designations and material certificate requirements for each line item.

Application compatibility is reviewed upon quotation; prices, shipping lead times and ex-works availability are confirmed in formal commercial offers.

Send your technical requirement

Select a process direction or send operating parameters with your reply contact. Valve execution, actuator sizing, positioner bus protocol and compliance documents are agreed in one enquiry.

Related industrial valve brands

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto in Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.