Specify Masoneilan valves and control packages from process conditions. Identify actuators, positioners and parts for installed assemblies through marking and records.
Valves and control devices
Identify independent products within the assembly and the required supply contents. New equipment needs a project datasheet.
35002 Camflex rotary valves
The 35002 Camflex rotary control valve uses an eccentric plug. For new equipment, provide the project datasheet; for a replacement, retain the complete installed designation and marking. Identify the actuator, positioner and required package contents separately.
21000 globe valves
The 21000 series uses a top-guided, unbalanced control-valve design. Supply process conditions, connections and package requirements for equipment selection. For an internal component, provide the reference and item position from the particular valve’s applicable documents.
41005 cage-guided valves
The 41005 series features cage guiding and balanced trim configurations. Keep its internal-component records separate from other valve series. Preserve the complete valve designation, trim information and applicable documentation; state project operating cases independently.
SVI positioners
Masoneilan documentation includes SVI II AP and SVI II ESD. Retain the complete instrument designation and its intended role in the control arrangement. Specify the positioner, mounting items and independently identified instruments separately, with their own references and project requirements.
4700 / 4800 P/E positioners
Models 4700P/4800P are pneumatic positioners; 4700E/4800E are electropneumatic. Preserve the suffix in the enquiry. Include the instrument marking, actuator interface records and required mounting components from the installed assembly documentation.
31/32 and 51/52/53 actuators
The official resource centre lists documentation for 31/32 and 51/52/53 actuators. Identify the actuator independently from the valve body. For replacement, provide its nameplate, complete type, existing assembly records and the list of components required in the supply.
78 air filter
The Masoneilan 78 air filter has its own technical documentation. Use the device’s marking and original references when requesting the product or its parts. Identify the air arrangement, connections and association with the actuator from the particular installed assembly drawing.
Trim and replacement components
List valve, actuator and positioner components separately. Attach the original reference, drawing position and quantity. For a kit, state its documented contents. A shared series name does not replace the configuration information needed to identify the particular item.
Selection inputs
Medium, inlet and outlet pressure, flow, temperature, connections and package requirements.
Components for an installed assembly
Valve and independent-device markings, original reference, drawing position, quantity and applicable document.
Valve, actuator and control instruments
Masoneilan is a Baker Hughes valve business. Separate the control valve, actuator, positioner and auxiliary devices when preparing a procurement enquiry. They may form one installed assembly while retaining independent designations and technical records.
An overall photograph explains the arrangement; legible nameplates identify the particular devices and their actual configurations.
Define whether the task concerns new equipment selected for process conditions, a repeat purchase of an identified product or replacement components for an existing assembly. New equipment needs a project datasheet. Replacement requests need current marking and installation records.
An internal part additionally requires its original reference or a position in the applicable product drawing.
Inputs for new equipment selection
State the process medium, its condition and composition, inlet and outlet pressure, temperature and flow. List different operating cases separately and retain the measurement units.
Include the purpose of the control loop and project limitations so the selection requirement is not reduced to a single average flow or the name of a process installation.
Describe connections from the project documents, including size, execution and applicable standard. For replacement in an existing pipe arrangement, attach the installation drawing and identify retained elements. Record body, trim and sealing requirements from the current assignment.
If the project changes, distinguish the new requirements from installed-equipment data and provide the current document revision.
Define the package boundary: valve alone, valve with actuator, or an assembly including a control instrument and mounting items. List the positioner and auxiliary devices independently. State required documents and accessories explicitly.
This allows the proposed contents to be checked line by line against the request rather than inferred from the main valve name.
Distinguishing the valve series
The 35002 Camflex is a rotary control valve with an eccentric plug. The 21000 uses a top-guided unbalanced design, while the 41005 features cage guiding and balanced trim configurations. These distinctions identify the enquiry direction.
The particular product still needs to be selected against the project requirements and documented equipment arrangement.
For a repeat purchase, retain the full designation, including suffixes and letter groups. Do not shorten it to the series name. Attach the earlier specification together with the actual marking, using current records after equipment modifications.
Identify retained elements of the installation separately so that the requested replacement boundary remains clear.
If new equipment is required in place of an existing valve, provide both the installed assembly data and the new technical assignment. Keep internal-part references associated with their own series and product documents.
Similar appearance or a shared application does not replace a documented comparison of the particular configuration, contents and interfaces.
Positioners and actuator interfaces
Identify the positioner from its own nameplate. Preserve all parts of SVI II AP and SVI II ESD designations and describe the instrument’s role within the existing arrangement.
For 4700 and 4800 models, retain P or E: the published product groups distinguish pneumatic and electropneumatic positioners. The generic term positioner does not identify a particular device.
Attach the actuator connection arrangement and the signal and interface requirements from the technical assignment. List mounting items, connections and independent auxiliary instruments using their own references. If only the instrument is requested, state that boundary.
For a package, keep an explicit contents list instead of allowing the main device name to stand for several separate items.
Configuration, function testing and commissioning belong to the responsible equipment team’s established procedures. The procurement enquiry should define hardware, contents and documents.
Describe software, diagnostic or service requirements separately when relevant; those requirements cannot be inferred solely from the general instrument or control-system name.
Actuators and air arrangements
Use the actuator’s own type and serial number where present. The valve identity establishes the parent assembly but does not replace actuator marking. Manufacturer documents include 31/32 and 51/52/53 families.
Provide the record applicable to the particular product and existing arrangement, listing required mounting components independently.
For an actuator component, state the original reference, assembly position and quantity. Define kit contents through the installed execution’s documentation, keeping kits separate from individual parts.
If marking is partially legible, attach several photographs and available earlier specifications. Leave uncertain characters identified as missing instead of copying a reference from a similar device.
List the 78 air filter and other independently identified auxiliary devices separately. Include marking, connection records and required contents. When several valve assemblies are involved, preserve each instrument’s association with its own installation.
A common arrangement drawing may support the list, while references, quantities and technical attachments remain linked to individual enquiry lines.
Trim, seals and replacement sets
An internal valve component needs the complete parent product designation, original reference and drawing position. Retain material and configuration information from the applicable record where provided. For multiple parts, use a table linking each item to its valve and documentation.
An overall photograph of the assembly supports that table but does not replace product references.
For seals or a replacement set, distinguish the number of kits from the number of individual items. Attach documented contents or a list of the particular components required. Keep parts for different valves separate.
When several installations are involved, identify the allocation to each unit and list additional reserve quantities independently from the current replacement need.
After valve or actuator modifications, compare the current configuration with the earlier spare-parts list. A previous order may be supplied for reference with its date and document revision. The enquiry must describe the actual installed product or an explicitly defined new requirement.
A reference from another installation does not establish the required configuration simply because the series matches.
Procurement list and contents checks
A useful table includes the installation, device type, full designation, original reference, serial number where present, quantity and attachment name. For a kit, add contents and number of kits. Separate required items, reserves and alternatives.
When the list changes, keep the revised version and identify rows where the reference, quantity or contents have changed.
Before ordering, state the document and marking requirements for the particular products. At receipt, compare designations, quantities and contents with the agreed list, retaining the documents alongside the corresponding equipment.
If the valve, actuator and positioner arrive as independently identified products, check each line while preserving its relationship to the requested project arrangement.
To begin selection, send a datasheet or marking photographs, the item list and available drawings. Add quantities, a work contact and destination. New valves need process conditions and the package boundary; replacement enquiries need the requested component references.
Mark missing information separately so subsequent clarification addresses actual gaps in the technical assignment.
Previous Masoneilan quotations
Our records include Masoneilan quotations. These enquiries are not presented as completed deliveries; new requests use current marking and technical requirements.
Confirmation of scope
Availability, price, lead time, distributor status, certificates and compatibility are not stated in advance. Configuration, supply scope and documents are confirmed for the specific enquiry.
Send the technical requirement
Send a datasheet or markings, the item list, quantities and a work contact.