Hansford Sensors vibration sensors
Technical selection of Hansford Sensors vibration sensors: HS-100, HS-150, HS-173 and HS-105 accelerometers, HS-420 and HS-421 4–20 mA transmitters, intrinsically safe HS-100I and HS-550 modules.
HS-100 accelerometers with 100 mV/g output
HS-100 compression accelerometers in a stainless steel body deliver a 100 mV/g acceleration signal via a 2-pin MS or M12 connector. Options run from 10 mV/g (±800 g) to 500 mV/g (±16 g), with 2 Hz to 10 kHz response at ±5%. They are rated −55 to +140 °C and IP68.
- Sensitivity 10–500 mV/g
- Response 2 Hz – 10 kHz ±5%
- Operates −55 to +140 °C, IP68
- Supply 18–30 V, bias 10–12 V
HS-150 shear accelerometers with M12 connector
HS-150 accelerometers use a shear-mode piezo element and deliver an acceleration signal via an M12 connector. Response is 1.5 Hz to 10 kHz at ±5%, the operating range is −55 to +150 °C and sealing is IP67. HS-AC010 straight and HS-AC011 right-angle cable assemblies fit the connector.
- Shear-mode piezo element
- Response 1.5 Hz – 10 kHz ±5%
- Operates −55 to +150 °C, IP67
- Cables HS-AC010 and HS-AC011
HS-173 triaxial accelerometers
The HS-173 triaxial accelerometer measures vibration in the X, Y and Z axes at once and outputs three acceleration signals via an M12 connector. It uses a shear-mode piezo element and an 8 Nm mounting torque. The stainless steel version weighs 235 g, the aluminium version 115 g.
- Three axes X, Y, Z on one M12
- Shear-mode piezo element
- Steel 235 g or aluminium 115 g
- Mounting torque 8 Nm
HS-105 accelerometers for hot machinery
HS-105 accelerometers work with an external charge amplifier and a low noise cable rated for 150 or 250 °C. The cable from sensor to amplifier is up to 20 m, and the total line length is up to 1000 m. Response is 2 Hz to 10 kHz at ±5%, and the sensor weighs 185 g.
- External charge amplifier
- Cable rated 150 or 250 °C
- 20 m to amplifier, 1000 m total
- Response 2 Hz – 10 kHz ±5%
HS-420 vibration transmitters with 4–20 mA output
HS-420 sensors convert vibration velocity into a 4–20 mA current signal for PLC and DCS systems. Ranges run from 0–10 to 0–100 mm/s with 10 Hz to 1 kHz response at ±5% to ISO 10816. The loop is powered at 15–30 V via a 2-pin MS connector.
- 4–20 mA current output
- Ranges 0–10 to 0–100 mm/s
- Response 10 Hz – 1 kHz, ISO 10816
- Loop supply 15–30 V
HS-421 dual output sensors: 4–20 mA and acceleration
The HS-421 delivers a 4–20 mA velocity signal for the PLC and an acceleration signal for a data collector at the same time via a 3-pin MS connector. The AC output is 100 mV/g for 0–10, 0–20 and 0–25 mm/s ranges and 50 mV/g for 0–50 and 0–100 mm/s. Rated −25 to +120 °C, IP68.
- 4–20 mA plus AC acceleration
- 100 mV/g up to 25 mm/s range
- 50 mV/g at 50 and 100 mm/s
- Operates −25 to +120 °C, IP68
HS-100I and HS-420I sensors for Ex zones
HS-100I intrinsically safe accelerometers are marked Ex ia IIC T4 Ga and Ex ia IIIC T130 °C for gas and dust zones at −55 to +110 °C. The mining version is marked Ex ia I Ma, and the HS-420I 4–20 mA transmitter has an M option for Group I. The HS-100I output is 100 mV/g.
- Marking Ex ia IIC T4 Ga
- Ambient −55 to +110 °C
- Mining version Ex ia I Ma
- One barrier per sensor circuit
HS-550 modules, HS-429 and HS-517 vibration trips
The HS-550 DIN rail TS35 module powers an accelerometer at 4 or 10 mA and amplifies the signal by x1, x10 or x100 from a 24 V ±10% supply. The HS-429 vibration trip gives a 4–20 mA output and a PNP switch up to 500 mA with a delay of up to 60 s. The HS-517 display works with HS-420 and HS-422.
- Gain x1, x10 or x100
- Sensor current 4 or 10 mA
- PNP switch output up to 500 mA
- Trip delay up to 60 s
Choosing a Hansford Sensors vibration sensor
Hansford Sensors manufactures acceleration-output accelerometers for data collectors and online systems (HS-100, HS-150, triaxial HS-173), 4–20 mA velocity transmitters for PLCs (HS-420) and dual output HS-421 sensors that provide both signals at once.
For hot machinery there is the HS-105 with an external charge amplifier and a cable rated for 150 or 250 °C. For Ex zones the intrinsically safe HS-100I is marked Ex ia IIC T4 Ga, with a mining version marked Ex ia I Ma.
System integration: modules, trips and switching enclosures
The HS-550 DIN rail module powers an accelerometer at 4 or 10 mA and amplifies the signal by x1, x10 or x100; the HS-429 vibration trip combines a 4–20 mA output with a PNP switch output up to 500 mA.
HS-SE switching enclosures provide a terminal where readings from several accelerometers are taken with a portable data collector, with multiple outputs via one connector.
Mounting and connection in hazardous areas
The sensor sits on a flat spot face of about 32 mm, is tightened to 8 Nm, and the cable is fixed with a bend radius of at least 80 mm; for the HS-420 the cable to the monitor does not exceed 300 m.
Each intrinsically safe sensor connects through its own Zener barrier or galvanic isolator listed on the data sheet; a temperature output needs a second barrier.
Hansford Sensors and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Hansford Sensors and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Meggitt Sensing Systems
- Equipment and parts for Bently Nevada
- Equipment and parts for Wilcoxon Sensing Technologies
- Equipment and parts for Kistler
Documents and sources
- Hansford Sensors — about the company
- Company history — milestones
- HS-100 accelerometer — product page
- HS-100 accelerometer — datasheet
- HS-150 accelerometer — datasheet
- HS-173 triaxial accelerometer — datasheet
- HS-105 high temperature accelerometer — datasheet
- HS-420 4–20 mA transmitter — product page
- HS-420 4–20 mA transmitter — datasheet
- HS-420 user guide — installation and maintenance
- HS-421 dual output sensor — datasheet
- HS-100I intrinsically safe accelerometer — datasheet
- HS-100I intrinsically safe accelerometer — product page
- HS-420I intrinsically safe transmitter — datasheet
- HS-550 vibration module — datasheet
- HS-429 vibration trip — datasheet
- HS-517 vibration trip display — datasheet
- Troubleshooting AC accelerometers — manufacturer article
- HS-661 accelerometer simulator — operating notes
- HS-660 cable and bias checker — datasheet
- HS-SE switching enclosure — datasheet