Vemat Motori / Vemat Electric Motors & Drive Components
Vemat Motori / Vemat industrial asynchronous motors: three-phase VTB series (IE1–IE4, IEC 56–630), single-phase & S3-50% compressor VMB/VMC, AC/DC brake motors, modular VTB-E/VTBw, NEMA SIE, and spare assemblies.
Three-phase motors VTB / 2VTB–4VTB
VTB, 2VTB, 3VTB, and 4VTB three-phase squirrel-cage asynchronous motors cover IE1 to IE4 efficiency classes, 2 to 8 poles, IP55 protection, IEC frame sizes 56 to 630, and 0.04 to 1400 kW. Units feature closed externally ventilated IC411 cooling. Standard mains are 230/400 V or 400/690 V.
- IE1 / IE2 / IE3 / IE4
- IEC 56 to 630
- 0.04 to 1400 kW
- IP55 / 2-4-6-8 poles
Single-phase series VMB & VMC
VMB and VMC single-phase squirrel-cage motors span IEC frame sizes 56 to 100 from 0.04 to 4 kW with permanent capacitor or electronic starting circuit breaker options. Motors are closed, externally ventilated, and rated IP55 for 2, 4, or 6 poles. High-torque options suit heavy starts.
- Series VMB / VMC
- IEC 56 to 100
- 0.04 to 4 kW
- IP55 · 2/4/6 poles
Single-phase compressor motors S3-50%
Vemat two-pole single-phase compressor motors span UNEL/IEC frame sizes 71 to 100 in duty S3-50%. Standard units come with power cable, manual-reset thermal switch, and anticlockwise shaft rotation view. Externally ventilated enclosures carry IP54 protection.
- Duty S3-50%
- IEC 71 to 100
- 2 poles · IP54
- Manual thermal reset
AC & DC brake electric motors
Vemat three-phase and single-phase brake motors with AC and DC electromagnetic brakes cover 0.04 to 160 kW. Spring-applied brake assemblies hold loads safely on hoists, conveyors, and indexing drives. Spare brake coils, friction discs, and rectifiers match frame sizes.
- AC & DC brakes
- 0.04 to 160 kW
- 1~ & 3~ models
- Coils, discs, rectifiers
Modular welded-frame VTB-E & VTBw
VTB-E and VTBw modular welded-steel high-voltage motors serve heavy industrial drives from 160 up to 3150 kW through IEC frame 630. Modular enclosures accept tailored cooling exchangers, RTD sensors, and heavy-duty bearing assemblies. Larger frames use open-type bearings with Tecalemit greasers.
- Series VTB-E / VTBw
- 160 to 3150 kW
- Welded steel housing
- Tecalemit lubricators
NEMA SIE, Ex & forced-cooled motors
Specialized Vemat Motori lines include low-voltage NEMA SIE motors (1 to 250 HP), explosion-proof units up to 315 kW, forced-ventilated VFD motors (0.06 to 250 kW), and traction motors from 50 to 1500 kW. Frames allow encoder and servo-blower mounting.
- NEMA SIE 1–250 HP
- Ex up to 315 kW
- Forced ventilation
- Traction 50–1500 kW
Shields DE/NDE, B5/B14 flanges & covers
Catalog exploded diagrams cover replaceable DE and NDE end-shields, B5 and B14 flanges, sx/dx mounting feet, cooling fans, fan covers, and Seeger retaining rings. Frames up to 132 use die-formed aluminum alloy housings, while 160 to 355 use integral grey-iron feet frames.
- DE & NDE shields
- Flanges B5 / B14
- Fan & fan cover
- Aluminum ≤132 / Iron ≥160
C40 shafts, bearings, seals & terminal box
All frames feature C40 steel shafts half-key dynamically balanced and Class F insulation with Class B temperature rise. Sizes 56 to 180 use pre-lubricated bearings (30,000 h direct-coupling life), while 200 to 355 use open bearings, shaft seals, and complete terminal boxes with Pg 11 to M76 glands.
- C40 steel shaft
- 30,000 h bearings
- Class F / IP55 seals
- Terminal box complete
Selecting Vemat Motori / Vemat asynchronous motors
Vemat Motori / Vemat three-phase squirrel-cage series VTB, 2VTB, 3VTB, and 4VTB cover IE1 through IE4 efficiency classes across UNEL/IEC frame sizes 56 to 630 (0.04 to 1400 kW, 2 to 8 poles). High-power modular welded-steel motors (VTB-E and VTBw) extend up to 3150 kW.
Single-phase VMB and VMC motors (frames 56 to 100, 0.04 to 4 kW) offer permanent capacitor or high-starting-torque electronic circuit breaker variants, alongside 2-pole IP54 compressor motors rated for S3-50% duty.
Housing alloys, C40 steel shafts & bearing architecture
Frames up to IEC 132 use die-formed aluminum alloy housings (with steel bearing seat inserts at 132), while IEC 160 to 355 use single-piece iron frames with integral feet. All shafts use C40 steel dynamically balanced with a half key.
Standard IP55 protection uses O-rings up to frame 180 and labyrinth seals from frame 200 upward; Class F insulation operates within Class B temperature rise. Frames 56 to 180 have pre-lubricated 30,000-hour bearings; 200 to 355 use open bearings with Tecalemit lubricators.
Nameplate data & spare assembly identification
Laser-marked Vemat Motori nameplates specify series code (VTB, VMB, VMC, SIE, VTB-E, VTBw), IEC frame, pole count, voltage (230/400 V or 400/690 V), mounting (B3, B5, B14, B34, B35), and AC/DC brake or forced-ventilation options.
Exact DE/NDE shields, B5/B14 flanges, fans, fan covers, and complete terminal boxes (glands Pg 11 to M76) match the frame and series exploded diagram.
Vemat Motori and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Vemat Motori and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Vecoplan
- Equipment and parts for Velan
- Equipment and parts for Vektek
- Equipment and parts for Velleman Instruments
Documents and sources
- Vemat Motori Product Range (Three-Phase & Single-Phase)
- Vemat Production Line & Automated Assembly
- About Vemat Motori S.r.l.
- DNV ISO 9001 Quality Management Certification
- Vemat Motori General Catalogue (PDF)
- Vemat IE3, Special Lines & Exploded Parts Catalogue (PDF)
- Vemat Technical Catalogue: Materials, Bearings & Insulation (PDF)
- Vemat Installation, Storage & Balancing Instruction Sheet (PDF)
