DD Scientific Electrochemical Gas Sensors

Teledyne DD-Scientific of Portchester, UK, has made electrochemical gas sensors since 2011 for oxygen, carbon monoxide, hydrogen sulphide, ammonia, ethylene oxide and other gases.

4-Series Toxic Gas Sensors: CO, H2S, SO2, NO2

GS+4CO measures carbon monoxide over 0–2000 ppm with a 70 ± 20 nA/ppm output, GS+4H2S covers hydrogen sulphide 0–100 ppm, GS+4SO2 sulphur dioxide 0–20 ppm and GS+4NO2 nitrogen dioxide 0–30 ppm. All run at 0V bias with a 3 pin 4-Series interface.

  • GS+4CO: CO 0–2000 ppm
  • GS+4H2S: H2S 0–100 ppm
  • GS+4SO2: SO2 0–20 ppm
  • GS+4NO2: NO2 0–30 ppm, UL2075

GS+4NH3 and DceL NH3 Ammonia Sensors

The ammonia range is split by span: GS+4NH3-100 covers 0–100 ppm with a 100 ± 30 nA/ppm output, GS+4NH3-1000 covers 0–1000 ppm and GS+4NH3-10000 covers 0–5000 ppm with a 10000 ppm overload. The low profile DceL NH3 covers 0–500 ppm and is interchangeable with 4-Series.

  • GS+4NH3-100: 0–100 ppm
  • GS+4NH3-1000: 0–1000 ppm
  • GS+4NH3-10000: 0–5000 ppm
  • DceL NH3: 0–500 ppm

Biased Ethylene Oxide and Nitric Oxide Sensors

GS+4ETO measures ethylene oxide over 0–20 ppm with a 1900 ± 600 nA/ppm output and requires +300mV bias. GS+7ETO in the 7-Series package gives 2600 ± 700 nA/ppm, and the medical MD+7ETO covers 0–5 ppm. GS+4NO measures nitric oxide 0–250 ppm, also at +300mV bias.

  • GS+4ETO: ETO 0–20 ppm
  • ETO and NO bias: +300mV
  • MD+7ETO: ETO 0–5 ppm
  • GS+4NO: NO 0–250 ppm

Oxygen Sensors: Lead, Lead-free and Partial Pressure

S+4OX covers 0–25% oxygen at 0V bias. The lead-free S+4OXLF and DceL OXLF require -600mV bias and offer 5 years+ typical life. S+AOX, S+EOX and the medical MD+VOX measure 0–100% oxygen with a 9–14mV output in air and a Molex connection.

  • S+4OX: 0–25% O2, 0V bias
  • S+4OXLF: -600mV bias
  • Lead-free: 5 years+ typical life
  • S+AOX, S+EOX: 0–100% O2

Low Profile DceL, MceL and Dual Toxic DT Sensors

The DceL package is interchangeable with 4-Series: DceL CO measures carbon monoxide 0–1000 ppm. The 4 pin GS+4DT measures CO 0–1000 ppm and H2S 0–100 ppm in one sensor. MceL 2ECO covers carbon monoxide 0–500 ppm with a 10 year life.

  • DceL CO: CO 0–1000 ppm
  • GS+4DT: dual CO and H2S channels
  • MceL 2ECO: 10 year life
  • DceL: 4-Series interchangeable

PCB-XXX Transmitters for 4-Series and DceL Sensors

The PCB-XXX transmitter works with 4-Series and DceL toxic sensors, biased and unbiased. It is supplied as a calibrated pair with the sensor. Outputs are ModBus, RS485, I2C and 4-20mA, and free software is supplied for fine tuning and programming of the PCB.

  • 4-20mA analogue output
  • ModBus, RS485 and I2C outputs
  • Supplied as a calibrated pair
  • Fits 4-Series and DceL sensors

Selecting a DD Scientific Electrochemical Sensor

A sensor is chosen by target gas, range and package. The 4-Series package is common in industrial gas detectors, the low profile DceL is interchangeable with it, MceL suits compact instruments, and 5-Series and 7-Series serve emissions and industrial safety instruments.

For oxygen choose lead OX sensors at 0V bias, lead-free OXLF sensors at -600mV bias with 5 years+ typical life, or AOX, EOX and VOX partial pressure sensors for 0–100% oxygen.

Instrument Integration and Outputs

The circuit depends on the number of pins and the bias: the manufacturer publishes 2-electrode, 3-electrode and 4-electrode circuits, plus circuits for Dual Toxic and biased sensors.

PCB-XXX transmitters are supplied as a calibrated pair with the sensor and offer 4-20mA, ModBus, RS485 and I2C outputs.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.