Klimawent industrial ventilation and filtration equipment

WPA centrifugal fans, UFO filtration units, and ERGO articulated extraction arms deliver dependable industrial air purification and local pollution capture across manufacturing plants.

Klimawent WPA-E, WPA-S, and WPA-P radial fans

Medium-pressure industrial centrifugal fans of the WPA series are designed to overcome high aerodynamic airflow resistance in local exhaust ventilation setups. Molded aluminum or welded sheet steel housings with epoxy powder coating protect interior air passages against abrasive wear and corrosion.

  • Stationary WPA-S-N fans equipped with anti-vibration mountings and flexible duct connectors
  • Wall-mounted WPA-E-N bracket fans engineered for direct integration into local duct lines
  • Mobile WPA-P-N extraction fans on wheeled chassis paired with heat-resistant intake hoses
  • Acoustic WPA-BOX sound-insulated enclosures reducing workplace noise levels below 65 dB

Klimawent UFO, BIG, and RAK filtration ventilation units

Stationary and mobile Klimawent air filtration appliances capture and purify air contaminated with welding fumes, grinding dust, and dry process particulates. Pleated cartridge and pocket filter media deliver high separation efficiency up to 99.9% for respirable dust fractions.

  • UFO-A-N units featuring automatic pneumatic pulse-jet cartridge cleaning via Venturi nozzles
  • Compact single-station mobile cleaners UFO-1000 and BIG-1000 handling dry shop dust
  • Dual-station RAK mechanical filtering units optimized for sticky, coarse welding particulates
  • Integrated ISKRA-10 spark arrestors preventing hot welding sparks from reaching filter media

Klimawent ERGO LUX and ERGO MINI articulated extraction arms

Self-supporting ERGO series extraction arms provide immediate point-of-source capture of hazardous fumes, dusts, and vapours generated during welding, brazing, and grinding. The internal pantograph joint structure guarantees smooth repositioning and stable hood holding.

  • ERGO LUX extraction arms offering operating reach radiuses from 2 to 4 meters
  • Compact ERGO MINI arms in 100 and 125 mm diameters for precision soldering and lab benches
  • Heavy-duty RO extension jibs up to 6 meters expanding operator working envelopes
  • Rotational capture hoods featuring manual airflow shut-off dampers and integrated lamps

SPARK-S/Ex and WPA-Ex explosion-proof ATEX roof fans

Engineered explosion-proof Klimawent ventilation units meet European ATEX safety standards for hazardous environments under categories 2G and 2D. Non-sparking brass liners and antistatic composite components eliminate ignition hazards during flammable vapour evacuation.

  • SPARK-S/Ex explosion-proof roof exhaust fans delivering flow volumes up to 27 500 m3/h
  • Centrifugal roof fans WPA-D-N/Ex featuring vertical air discharge configurations
  • Wall-bracket and portable hazardous duty extractors WPA-E-N/Ex and WPA-P-N/Ex
  • High-efficiency SMART-EC general ventilation roof fans powered by brushless EC motors

Klimawent ALAN and KOS vehicle exhaust extraction systems

Systems engineered for capturing toxic vehicle exhaust emissions directly from tailpipes during indoor engine diagnostics and testing in maintenance depots and fire garages. Flexible extraction hoses withstand continuous exhaust temperatures up to +650 deg C.

  • Spring-recoil ALAN-N hose reels with mechanical ratchets for automated hose storage
  • Motorized ALAN-HD-N reel extractors built for heavy industrial and commercial vehicles
  • Extruded aluminum extraction rails KOS-AL supporting smooth sliding exhaust trolleys
  • Thermal-resistant clamp-on nozzles and pneumatic exhaust tailpipe couplers

MISTOL-MIX oil mist separators and STORM-H cyclone filters

Specialized industrial filtration systems capturing oil mists, coolant vapours, and emulsion aerosols released during high-speed metal cutting on CNC machinery. Multi-stage centrifugal separation recovers coolants for closed-loop return to machine sumps.

  • MISTOL MIX-1000 and MIX-2000 separators combining droplet catchers and HEPA filters
  • Centrifugal cyclone separators STORM-H engineered for heavy particulate pre-cleaning
  • Electrostatic station filters PROTON effective against fine oil aerosols and fumes
  • Siphon-equipped drainage ports ensuring automated oil drainage and coolant reclaim

Klimawent replacement filter cartridges, hoses, and ducts

A full portfolio of maintenance consumables and connection elements engineered for routine servicing of Klimawent aspiration plants. Timely filter renewal maintains designed airflow capacities and shields fans against dust accumulation.

  • Pleated polyester filter cartridges with PTFE membrane linings for UFO and BIG units
  • Flexible high-temperature extraction hoses Carflex-200, Carflex-300, and Master-Clip
  • Abrasion-resistant polyurethane spiral ducts belonging to the PUR-PU heavy series
  • Pre-filter inserts, metallic grease filters, and spark-arresting baffle meshes

Control cabinets, automation units, and fan drive components

Electric drive components, automated starter panels, and velocity controllers configured for Klimawent industrial air systems. Precise parts matching according to manufacturer wiring schematics and serial numbers.

  • Motor protection starters and automated control panels with overload trip relays
  • Dynamically balanced radial impellers engineered for WPA series centrifugal fans
  • Differential pressure switches monitoring filter bag loading and airflow drops
  • Mounting brackets, roof curbs, circular transition flanges, and rubber dampeners

Aerodynamic sizing and selection of WPA radial exhaust fans

Klimawent WPA series industrial radial centrifugal fans are engineered to transport particulate-laden air through extended ducting networks in local exhaust ventilation systems.

System calculations require accurate assessment of total aerodynamic friction losses across duct elbows, filter elements, and capture hoods.

Backward-curved centrifugal impellers ensure superior energetic efficiency and stable operating air delivery without overloading electric motors during variable duct flow conditions. Solid molded aluminum or welded structural steel housings withstand mechanical vibration effectively.

Preventive servicing includes dynamic impeller balancing checks and electric motor bearing lubrication.

Pneumatic reverse pulse cartridge cleaning in UFO-A-N units

Filtration ventilation units of the UFO-A-N family are equipped with pleated polyester filter cartridges coated with microporous PTFE membranes. To eliminate accumulated particulate cakes from the outer cartridge media, an automated reverse pulse pneumatic system is employed.

A dedicated compressed air accumulator injects brief pressure pulses through solenoid valves into Venturi nozzles positioned directly above each cartridge. The resulting supersonic shock wave detaches dust layers instantaneously, directing them into a collection drawer.

Continuous differential pressure transmitter readings optimize pulse cycle intervals while conserving factory compressed air.

Kinematic design and balance adjustment of ERGO LUX extraction arms

Self-supporting articulated ERGO LUX extraction arms capture airborne fumes and hazardous gases directly at the welding or metal cutting source.

An internal kinematic mechanism consisting of aluminum linkages and tensioned counterbalancing springs holds the capture hood securely in any three-dimensional spatial orientation. Friction disks fitted with adjustable tension bolts allow operators to tune articulation stiffness precisely.

The intake hood incorporates a full rotational collar and an integrated manual throttle damper, enabling operators to close off branch airflow during work breaks to conserve central fan energy.

ATEX explosion protection engineering for SPARK-S/Ex roof exhausters

Klimawent SPARK-S/Ex series roof ventilation fans strictly comply with European ATEX safety directives for industrial hazardous locations handling flammable gas and vapour mixtures under categories 2G and 2D.

To prevent mechanical friction sparks, inner air contact surfaces feature protective non-sparking brass containment rings that eliminate potential impeller contact with steel shroud components. Explosion-proof electric motors feature embedded thermistors monitoring winding temperature continuously.

Antistatic composite external housings prevent hazardous electrostatic charge accumulation in outdoor rooftop atmospheres.

Automated vehicle exhaust evacuation via ALAN reels and KOS channels

Indoor evacuation of hazardous internal combustion engine exhaust emissions within service facilities and emergency vehicle depots relies on ALAN hose reels and KOS-AL extruded aluminum rail ducts.

A heavy-duty spring-driven recoil mechanism spools flexible heat-resistant rubber hoses automatically, keeping maintenance bay floors clear and unobstructed. Continuous aluminum extraction channels with rubber sealing flaps permit sliding carriages to track vehicles smoothly along service lanes.

High-temperature rubber or stainless steel exhaust tailpipe adapters with mechanical clamps or pneumatic cuffs ensure leak-free coupling.

Oil mist and coolant aerosol separation on precision CNC machine tools

High-speed metal machining operations generate substantial volumes of hazardous oil mists and water-soluble coolant aerosols.

Klimawent MISTOL-MIX filtration appliances utilize a proven three-stage separation layout: an inertial droplet pre-separator, a synthetic pocket filter, and a downstream HEPA final filtration cartridge.

Coalesced oil droplets accumulate along internal housing walls and drain automatically via a siphon trap back into the machine tool coolant reservoir. This process cuts cutting fluid consumption, protects sensitive electronic controller enclosures, and maintains clean air.

STORM cyclone pre-separators for coarse abrasive dust capture

To protect fine filtration stages from premature clogging and abrasive wear in metal fabrication and woodworking lines, Klimawent STORM series cyclone separators are installed upstream of primary filter units.

Centrifugal separation of coarse particulates captures up to ninety percent of heavy dust before the air stream enters cartridge or pocket collectors.

The tangential inlet nozzle generates a descending spiral vortex, throwing heavy particles toward the conical walls where they drop into a sealed collection hopper fitted with a manual or rotary valve.

Incorporating cyclone pre-cleaners significantly extends filter cartridge service life and reduces scheduled maintenance overhead during continuous multishift plant operation.

Flexible extraction ducting, high-temperature hoses, and automated control cabinets

Reliable operational performance of local exhaust systems depends directly on proper selection of flexible duct connections and integrated automation panels.

For articulated arms and mobile extraction units, Klimawent utilizes wear-resistant polyurethane hoses reinforced with copper-coated spring steel spirals, resisting abrasive friction and negative pressure collapse.

In vehicle exhaust extraction networks, multilayer vulcanized rubber and high-temperature fabric hoses maintain structural flexibility under hot engine exhaust contact.

Dedicated electrical control enclosures provide smooth motor startup, overload protection, automated pulse cleaning valve sequencing, and seamless supervisory bus integration.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.