Instrumentation and sensors for KOBOLD / KOBOLD Messring GmbH

Industrial process instrumentation by KOBOLD / KOBOLD Messring GmbH: electromagnetic flow meters, rotameters, pressure transmitters, bypass level gauges, and RTD switches.

Magnetic-inductive flow meters KOBOLD / KOBOLD Messring GmbH MIM and MIK

Compact magnetic-inductive flow meters KOBOLD MIM and MIK series measure and batch conductive liquids across industrial process lines. Stainless steel transmitter housing paired with a bright TFT screen provides instant readouts of volumetric flow rates, accumulated totals, and medium temperature.

  • Bidirectional volumetric flow measurement for conductive fluids from 0.01 to 350 l/min
  • Integrated medium temperature sensor and configurable analog outputs with IO-Link protocol
  • Robust stainless steel housing incorporating optical touch keys for convenient operation
  • Exceptional stability against flow turbulence and hydraulic surges across industrial lines

Variable area flow meters KOBOLD / KOBOLD Messring GmbH KSK and KSM

Plastic variable area flow meters KOBOLD KSK and KSM series deliver direct visual flow monitoring for aggressive and pure fluids across chemical processing circuits. Conical measuring tubes made of polysulfone or trogamid house magnetic floats that actuate external bistable reed switches.

  • Durable conical flow tubes made of chemically resistant polysulfone or trogamid plastic
  • Adjustable external bistable magnetic reed contacts for minimum and maximum flow alerts
  • Direct flow reading via high-contrast scale calibrated for water or process gas flows
  • Threaded or glued socket end connectors facilitating direct installation into pipework

Coriolis mass flow meters KOBOLD / KOBOLD Messring GmbH TMU and TME

Precision Coriolis mass flow meters KOBOLD TMU, TME, and HPC series execute direct multi-parameter measurement of mass flow, density, and medium temperature for challenging fluids. Absence of moving internal components inside dual oscillating tubes ensures exceptional zero-point reliability.

  • Simultaneous true mass flow, volumetric flow, medium density, and temperature metering
  • Superior measurement accuracy reaching 0.1 percent unaffected by fluid viscosity changes
  • Thermal resilience handling cryogenic and high-temperature streams from -40 up to +260 C
  • Digital Modbus and HART communication options paired with galvanic isolated 4-20 mA links

Pressure transmitters KOBOLD / KOBOLD Messring GmbH PAD and PMP

Intelligent pressure and differential pressure transmitters KOBOLD PAD, PAS, and PMP series deliver dependable monitoring across severe plant environments. Piezoresistive and capacitive sensor elements equipped with DRM diaphragm seals safeguard measurement integrity in aggressive media.

  • Differential and gauge pressure measurement spans extending from 0.75 mbar up to 600 bar
  • Integrated HART communication protocol enabling remote zero calibration and diagnosis
  • Diaphragm seals engineered in Hastelloy, tantalum, or stainless alloy for chemical duty
  • High static overload capability protecting internal sensor cells against line surges

Bypass level indicators KOBOLD / KOBOLD Messring GmbH NBK and NWS

Magnetic bypass level indicators KOBOLD NBK series deliver reliable visual and automated level monitoring on pressurized tanks and boiler drums. The external two-color magnetic roller scale maintains unambiguous level indication even during electrical utility blackouts.

  • Design pressure ratings up to PN 320 and operational fluid temperatures reaching +400 C
  • Mounting options for magnetostrictive continuous transmitters with 4-20 mA analog outputs
  • Adjustable external magnetic switches NBK-R for high and low liquid level alarms
  • Titanium and acid-resistant stainless alloy floats engineered for aggressive densities

Digital temperature switches KOBOLD / KOBOLD Messring GmbH TDD and TDA

Digital temperature switches KOBOLD TDD, TDA, and TNS series monitor and regulate thermal cycles across hydraulic packs, gear drives, and machine cooling loops. The bright LED display shows live temperatures and simplifies programming dual transistor switching thresholds.

  • Precision platinum Pt100 sensing elements meeting Class A accuracy specifications
  • Dual independent semiconductor PNP or NPN outputs with configurable switching hysteresis
  • Rotatable display housing fabricated from stainless steel rated for IP65 environments
  • Protective stainless thermowell sleeves designed for pressurized industrial fluid lines

Installation and Commissioning of MIM and MIK Flow Meters

Proper installation of KOBOLD / KOBOLD Messring GmbH MIM and MIK series electromagnetic flow meters guarantees high measurement precision for conductive process streams.

Prior to mounting the flow sensor into piping, engineers must ensure straight calming pipe runs of at least five nominal pipe diameters upstream and three diameters downstream from the sensor.

The flow tube must remain completely filled with liquid during all pumping operations; vertical upward flow orientations are strongly recommended.

Establishing dependable grounding connections between the sensor body, ground electrodes, and adjacent pipework prevents stray electrical potentials originating from variable frequency drives from distorting analog 4-20 mA transmission signals.

Selection and Maintenance of KSK Variable Area Flow Meters

KOBOLD KSK and KSM variable area flow meters deliver direct visual flow monitoring for water, saline solutions, and aggressive chemical reagents.

When selecting a flow meter, operating pressure, system temperature, and fluid density must be evaluated because metering floats are calibrated for specific fluid densities.

Routine maintenance involves examining the internal conical polysulfone flow tube for mineral deposits or suspended solid buildup.

Cleaning the metering tube requires gentle flushing with neutral detergent solutions without abrasive brushes, safeguarding internal flow tube contours and maintaining precise scale calibration alignment across long operational runs.

Calibration and Operation of TMU Coriolis Mass Flow Meters

KOBOLD TMU series Coriolis mass flow meters provide multi-parameter measurement of liquid and gas mass flow without sensitivity to fluid viscosity or velocity flow profiles.

To eliminate external structural strain on oscillating measuring pipes, the flow meter must be supported on rigid framework without piping overhang on connecting flanges.

During plant commissioning, operators execute zero-point calibration routines under completely filled, zero-flow conditions at operating temperature.

Ongoing monitoring via Modbus or HART digital interfaces tracks dual-tube resonance frequencies, enabling early detection of sticky fluid coatings or erosive thinning of internal sensor tubes.

Protecting PAD and PMP Pressure Transmitters with Diaphragm Seals

Deploying KOBOLD PAD, PAS, and PMP pressure transmitters on pulsating lines or severe process media requires DRM diaphragm seals. The flexible diaphragm barrier isolates sensitive piezoresistive sensor elements from direct exposure to crystallizing, hot, or viscous chemicals.

The internal fill chamber contains vacuum-degassed silicone oil transmitting line pressure smoothly without thermal lag.

To mitigate hydraulic shocks originating from rapid-closing shutoff valves, an impulse siphon loop or an adjustable needle snubber is installed upstream, protecting the silicon sensing chip from irreversible strain and overload.

Inspection Protocol for NBK Bypass Level Indicators

KOBOLD NBK series magnetic bypass level indicators mount directly to tanks and distillation vessels utilizing communicating vessel physics for liquid level indication.

Routine servicing requires checking free axial movement of the cylindrical float within the non-magnetic titanium or stainless steel bypass tube.

Periodically flushing the bypass column through the lower drain port removes accumulated sludge, preventing buildup from arresting internal permanent magnets.

When adjusting external NBK-R reed contacts or 4-20 mA transmitters, technicians verify crisp flipping response of two-color indicator rollers as the float traverses vessel height.

Configuring TDD Electronic Temperature Switches and Thermowells

KOBOLD TDD digital temperature switches and TDA sensors safeguard hydraulic power units, gear drives, and bearing blocks against critical thermal overheating.

Mounting the Pt100 platinum RTD element inside a solid-machined stainless thermowell seals the pressurized pipework, allowing probe servicing without shutting down line pressure.

Using the digital programming buttons, operators configure independent setpoints for early thermal warning and emergency equipment shutdown. Setting switching hysteresis prevents rapid relay chatter when temperatures hover near trip thresholds, prolonging electrical contact service life.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.