Karl Dungs / DUNGS Gas Controls, Safety Shut-Off Valves and Pressure Switches

We identify and quote Karl Dungs (DUNGS) GasMultiBloc combination controls, safety solenoid shut-off valves, gas pressure switches, and regulators by technical specifications.

Karl Dungs / DUNGS Multifunctional Gas Controls GasMultiBloc

Karl Dungs / DUNGS GasMultiBloc systems integrate gas filtration, pressure regulation, and dual safety shut-off valves within a single compact module. Engineered for industrial combustion burners, this design delivers smooth progressive ignition and dependable isolation up to 360 mbar.

  • Integrated pressure regulator and twin automatic shut-off valves in a unified body.
  • Operating inlet pressure rating up to 360 mbar with adjustable start gas volume flow.
  • Fine mesh strainer shielding valve seats against pipeline debris and pipe scale.
  • Direct mounting ports for pressure switches and leak detection without external piping.

Karl Dungs / DUNGS Automatic Gas Safety Shut-Off Valves DMV and MVD

Karl Dungs / DUNGS DMV and MVD solenoid safety shut-off valves provide fast emergency isolation and reliable fuel gas control for burner lines. Featuring EN 161 Class A sealing integrity, these valves close in under one second to safeguard high-capacity thermal processing equipment.

  • Single and double valve bodies actuated by rapid-closing electromagnetic solenoids.
  • Class A leak-tight isolation with closing response times under one second.
  • DLE configurations equipped with hydraulic damping for smooth burner firing.
  • Threaded and flanged connections spanning sizes from DN 15 to DN 150.

Karl Dungs / DUNGS Gas and Air Pressure Switches GW and LGW

Karl Dungs / DUNGS GW and LGW pressure switches monitor operating thresholds for fuel gases, air, and flue streams across industrial heating plants. High-grade elastomeric diaphragms actuate precise microswitches to trigger safety interlocks whenever line pressures cross target setpoints.

  • Adjustable operating ranges spanning from 0.4 to 500 mbar with dial indicators.
  • Diaphragm sensing elements maintaining trip repeatability across wide temperature bands.
  • Manual reset lockout variants for boiler overpressure and underpressure protection.
  • Weather-resistant enclosures rated IP54 with accessible electrical termination hubs.

Karl Dungs / DUNGS Gas Pressure Regulators FRS and FRM

Karl Dungs / DUNGS FRS and FRM spring-loaded gas regulators maintain constant downstream pressure despite inlet pressure variations or fluctuating burner demand. An internal balancing diaphragm counteracts supply surges to stabilize flame geometry in industrial process furnaces.

  • High flow capacities handling upstream inlet pressures up to 1000 kPa in FRM models.
  • Balancing diaphragm neutralizing inlet pressure swings to stabilize outlet flow.
  • Interchangeable color-coded springs for exact tuning to burner firing requirements.
  • Internal pulse lines eliminating external impulse tubing for compact installations.

Karl Dungs / DUNGS Valve Proving Systems VPS 504

Karl Dungs / DUNGS VPS 504 valve proving systems verify the seat tightness of dual safety shut-off valves prior to ignition or following burner shutdown. An autonomous micro-pump pressurizes the intermediate chamber, triggering an electrical interlock if leakage exceeds permissible limits.

  • Autonomous motor-driven diaphragm pump generating independent test pressure.
  • Short test cycle spanning 10 to 26 seconds to minimize pre-purge boiler delays.
  • Multi-color indicator lights communicating operating status and fault lockouts.
  • Flanged adapter kits mounting directly to DMV valves and MultiBloc housings.

Karl Dungs / DUNGS Microprocessor Burner Controls MPA 41xx

Karl Dungs / DUNGS MPA 41xx burner management controllers supervise the purge, ignition sequencing, and flame monitoring of forced-draught industrial burners. The digital microprocessor architecture processes ionization rod and UV sensor signals to guarantee fail-safe combustion control.

  • Multi-stage and modulating firing management for forced-draught burners.
  • Dual-channel flame detection supporting ionization rods and UV optical sensors.
  • Digital bus communication interfaces relaying operating data to plant SCADA networks.
  • Non-volatile diagnostic fault memory recording shutdown histories for service teams.

Karl Dungs GasMultiBloc Multifunctional Gas Controls for Industrial Burners

Karl Dungs GasMultiBloc modular systems series MBE, MBC, and MB-DLE combine a fine-mesh filter, a spring-loaded pressure regulator, and two Class A automatic safety shut-off valves in a unified compact assembly.

Engineered for modulating and two-stage gas burner systems, the integrated design reduces gas train installation dimensions and eliminates intermediate connecting nipples. The unified housing withstands operating pressures up to 360 mbar with rapid shut-off response times under one second.

When requesting technical selection, provide inlet and required downstream gas pressure, maximum fuel flow rate, burner model, and electrical supply voltage.

Karl Dungs DMV and MVD Solenoid Safety Shut-Off Valves for Gas Lines

Fast-closing solenoid safety shut-off valves Karl Dungs series DMV, MVD, and SV provide automatic fuel gas isolation for boiler rooms and industrial furnaces.

Available in single and compact double valve configurations from DN 15 to DN 150, these units maintain Class A tightness with zero leakage under high pressure. DLE versions integrate a hydraulic damper to deliver smooth adjustable opening for soft burner ignition and flame stability.

The rugged aluminum body and high-temperature NBR seals ensure long operational life across demanding industrial environments. For technical inquiries, confirm pipeline bore size, working gas pressure, opening speed, and solenoid coil ratings.

Karl Dungs GW and LGW Pressure Switches for Safety Interlock Circuits

Karl Dungs diaphragm pressure switches series GW A5, GW A6, LGW A2, and LGW A4 monitor positive, negative, and differential pressures in gas and combustion air ducts. High-precision elastomeric measuring diaphragms actuate gold-plated microswitches, preventing false trips from industrial vibrations.

The devices safeguard burner firing by verifying minimum gas supply pressure, air blower draft, and filter differential loading. Weatherproof IP54 housings feature calibrated setting dials for convenient commissioning and tuning.

When ordering pressure switches, indicate process fluid, required adjustment range in millibars, electrical connection style, and manual reset lockout needs.

Karl Dungs FRS and FRM Spring-Loaded Gas Pressure Regulators

Karl Dungs pressure regulators series FRS and FRM deliver accurate pressure reduction and maintain stable downstream pressure despite fluctuating inlet pressures or changing burner demands.

An internal balancing diaphragm counteracts inlet pressure swings against the valve seat, increasing regulating accuracy across all firing loads. FRM models handle medium inlet pressures up to 1000 kPa, making them suitable for commercial and district gas reducing stations.

When dimensioning a gas regulator, state upstream supply pressure, target downstream operating pressure, flow rate variations, gas relative density, and pipeline flange standards.

Karl Dungs VPS 504 and VDK Valve Proving Systems for Seat Integrity

Automatic valve proving systems Karl Dungs VPS 504 and VDK test the closure tightness of dual solenoid safety shut-off valves before burner ignition or immediately after shutdown.

An integrated motor-driven diaphragm pump pressurizes the intermediate chamber between valve seats without venting fuel gas to the ambient boiler room. The electronic monitoring module measures pressure trends during a short testing cycle lasting 10 to 26 seconds.

When submitting an inquiry for a VPS system, specify the valve group model, intermediate test volume between valves, supply voltage (230 VAC or 24 VDC), and flanged adapter hardware.

Karl Dungs MPA 41xx Microprocessor Burner Management Controllers

Digital burner management systems Karl Dungs series MPA 41xx and MPA 22xx supervise automatic burner start-up, furnace pre-purge timing, and continuous flame supervision.

The microprocessor architecture monitors ionization rods, optical UV sensors, pressure limiters, and modulating air dampers to ensure fail-safe operation. Integrated industrial communication interfaces allow seamless data exchange with plant SCADA and boiler automation networks.

Non-volatile error memories record trip histories for efficient troubleshooting. To specify a burner controller, state burner firing mode, modulation control type, flame sensor technology, and required purge timing.

Karl Dungs / DUNGS and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Karl Dungs / DUNGS and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

QR code to open Telegram: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.