Aimtec is a modular power supply manufacturer founded in 2002 and headquartered in Montreal, Canada.
Select AC/DC and DC/DC converters for a board or cabinet by input, output, isolation and mounting.
Product families
First identify the conversion: mains AC/DC, DC/DC from a DC bus, or regulation within a board. Then select power, output count and mounting. Isolated and non-isolated designs, and regulated and unregulated outputs, serve different requirements. An inquiry may combine several components for one instrument, with separate requirements for each power rail.
AMEM1/3/5-EZ compact AC/DC
Modules rated at 1/3/5 W for compact boards. Input is 90–264 VAC or 120–370 VDC, isolation 3000 VAC, package 1×1×0.63 inches. Select power and output voltage for the load, and mounting for the space and pin layout.
Provide load requirements and the power diagram; for replacement, include the full code and board photographs. Allow for clearance and heat dissipation.
Model, load requirements and connection arrangement
AME0FL10-480LPZ wide input
A 10 W AC/DC converter accepting 85–528 VAC or 100–745 VDC. Its regulated output has overload, overvoltage and short-circuit protection. Consider this family when the supply range exceeds a conventional mains module. State output voltage, current, mounting dimensions and enclosure conditions.
For repair, retain the 480LPZ suffix and include pin photographs to determine the electrical and mechanical version.
Model, load requirements and connection arrangement
AMEDX-NZ DIN-rail power
Enclosed AC/DC supplies with DIN mounting, rated at 15/30/60/75/100/120/150 W. Input is 85–264 VAC, output versions 5–48 VDC, isolation 4000 VAC. Select power for the relevant supply rail and the enclosure for available space and wiring.
State output voltage, current, free rail width and connected equipment. For replacement, include terminal photographs and the complete designation.
Model, load requirements and connection arrangement
AMESP750U-277JZ fanless 750 W
A narrow, enclosed 750 W AC/DC supply with 85–305 VAC input and 12–48 V output versions. Cooling is fanless, with full power up to +45 °C. Closed cabinets require attention to ambient temperature and nearby heat sources. Provide load voltage and current, dimensions and mounting method.
For replacement, include the complete JZ designation and connection photographs.
Model, load requirements and connection arrangement
AM40CW-NZ 40 W in 1×1 inch
A regulated 40 W DC/DC module in a 1×1 inch package. The two 4:1 input ranges are 9–36 and 18–75 VDC, with output versions from 3.3–28 VDC. Suitable for distributed power from a common DC bus. State input range, output voltage and current.
Board replacement also requires height, pin spacing and the installed converter marking.
Model, load requirements and connection arrangement
AM80EW-LPZ up to 80 W
An isolated DC/DC module measuring 50.8×25.4×11.8 mm. Inputs are 9–36 or 18–75 VDC, with 3.3/5/12/15/24 V outputs; selected models deliver up to 80 W. Remote enable and output trimming are provided. Options include a heatsink, screw terminals and DIN mounting.
State the installation, supply range and load to select the electrical model and mechanical package.
Model, load requirements and connection arrangement
AM1DM-EZ medical DC/DC 1 W
An isolated 1 W SIP7 module with an unregulated output. The medical family specifies 1 MOPP and 2 MOOP, with 5000 VAC or 6000 VDC isolation depending on the model. Selection depends on the instrument's isolation barrier and permitted supply variation.
State input and output voltages, load behavior and mounting space. For replacement, preserve the full code and circuit requirements.
Model, load requirements and connection arrangement
AM50QB/75QB/100QB-JZ railway
Railway quarter-brick DC/DC converters rated at 50/75/100 W. Input versions extend to 40–160 VDC, with 3000 VAC isolation and EN50155 compliance. Select for the onboard supply and load; the railway label alone does not define configuration.
Provide input range, output voltage and current, cooling and mounting. For replacement, include the part marking and remote-control connections.
Model, load requirements and connection arrangement
AM150HB-JZ and AM250HB-JZ
Railway half-brick DC/DC modules rated at 150 and 250 W. Features include Remote On/Off, Remote Sense voltage-drop compensation and output trimming. Match power requirements to the control and feedback circuits. State onboard supply, loads, cooling and mounting.
For expansion, include the connection diagram and identify retained modules to specify the new assembly around the existing installation.
Model, load requirements and connection arrangement
AMSR3-EZ 3 A regulator
A switching regulator with 3 A output, 8–36 V input and SIP12 packaging. Operating temperature is −40…+85 °C. Select output voltage for the loads and available mounting space in the board or instrument. Provide the supply diagram, current, dimensions and pin layout.
For an alternative to another regulator, include its datasheet to compare electrical function and packaging.
Model, load requirements and connection arrangement
AMER60E-Z constant-current driver
A 60 W AC/DC LED driver accepting 90–305 VAC. The main output is 5–55 V at 1.1 A, with an always-on 12 V auxiliary output and IP67 metal enclosure. Select for the LED string and auxiliary supply. State series arrangement, current, string voltage and installation location.
Distinguish this constant-current driver from a constant-voltage supply of equal power.
Model, load requirements and connection arrangement
AM1GU-LPZ and AM3GU-LPZ SIP8
Regulated 1 and 3 W DC/DC modules with 4.5–36 VDC input and 3000 VDC isolation. SIP8 dimensions are 22×9.5×12 mm; single and bipolar outputs are available. For interface and measuring circuits powered from a shared bus, provide input range and every output requirement.
Positive and negative rails require separate current specifications and the load connection diagram.
Model, load requirements and connection arrangement
AM1DS-EZ and AM2DS-EZ SIP7
DC/DC modules rated at 1 and 2 W in SIP7. Nominal inputs of 3.3/5/9/12/15/24 V are separate versions; isolation is 1500 or 3000 VDC depending on the model. Select the supply rail, output and isolation version. Provide markings, load data and dimensions.
Appearance-based replacement also needs board photographs showing the pins to compare electrical connections.
Model, load requirements and connection arrangement
AM1SS-EZ and AM2SS-EZ SIP4
Converters rated at 1 and 2 W with four pins in SIP4. Isolation is 1500 or 3000 VDC; nominal input and output depend on the version. The compact package helps when board area is limited, but selection starts with the circuit. Provide input, output, current and full code.
For replacement, include board and marking photographs.
Model, load requirements and connection arrangement
AMEOF30-JZ open-frame AC/DC
An open-frame 30 W supply with 85–264 VAC or 100–370 VDC input and 3000 VAC isolation. Protection covers short circuit, overcurrent and overvoltage. Select outputs and physical configuration around the protective enclosure. Provide mounting space, fixing-hole positions and load connections.
Replacement must preserve mechanical installation and wiring as well as power; photographs of the installed unit are useful.
Model, load requirements and connection arrangement
AM2DM-EZ medical DC/DC 2 W
A 2 W medical SIP7 module with an unregulated output. Nominal inputs are 3.3/5/12/15/24 V, with full power up to +85 °C. Provide load range, output and isolation requirements from the instrument documentation. Replacement must preserve circuit behavior as consumption changes.
Include the code, pin layout and enclosure conditions; increased power also requires consideration of heat dissipation.
Model, load requirements and connection arrangement
Provide minimum and maximum input voltage, output and current, output count, load behavior and internal temperature. Add isolation requirements, mounting dimensions and connections. Bipolar circuits need both rail specifications; LEDs need operating current and string voltage.
A diagram or specification links these requirements to a particular converter.
Individual modules and complete packages
Repair usually requires a specific module with its full code and suffix. A new product needs a list of power rails and a mounting choice: board, open-frame, enclosed or DIN rail. Include project samples and assembly quantities in the same inquiry.
For an alternative brand, provide both datasheets and identify the mandatory characteristics.
Send the requirements and package
Send the full code or selection parameters, quantity and destination. List package items separately with their application. For replacement, include enclosure, pin and mounting photographs. Price, lead time and scope are agreed during quotation; suitability for a circuit follows its documentation. We are neither an authorized dealer nor the manufacturer's representative.