HVAC, REFRIGERATION AND BUILDING CONTROL

Johnson Controls equipment and controls

Source Johnson Controls equipment and controls for building engineering systems. Send a specification or an installed-device model so the application, configuration and connection requirements can be checked.

Choose a system or device type

Start with the component duty and specific product line. The Johnson Controls name alone does not identify the generation, regional version or compatibility. The residential and light commercial HVAC business, including the Hitachi joint venture, transferred to Bosch on 1 August 2025. The groups below cover confirmed Johnson Controls lines and commercial YORK chillers. Manufacturer announcement.

Metasys building automation

Metasys combines monitoring and control of building systems. Component replacement depends on the existing architecture, software version and integration interfaces; a shared brand does not establish compatibility.

For selection: Full controller code, Metasys version, component duty, network diagram and input/output list.

Manufacturer information

Facility Explorer controllers

Facility Explorer includes equipment and supervisory controllers. FX90 is a newer generation of supervisory controller than FX80; migration requires checking platform version and licences.

For selection: Full part number, FX80 or FX90, platform version, licences, connected devices, network type and configuration backup.

Manufacturer information

Control valves

VG1000 is a ball-valve family; VG7000 uses globe valves. Valve body and actuator must be selected together. Number of ways, flow characteristic and permitted media depend on the configuration.

For selection: Body and actuator codes, nominal size, Kvs/Cv, two or three ways, connection, medium, temperature and differential pressure.

Manufacturer information

Manufacturer information ↗

Valve and damper actuators

M9100 and VA9100 in the official non-fail-safe group are electric actuators without spring return. Valve and damper applications require checking mounting and mechanical connection.

For selection: Full code, voltage, control signal, torque or thrust, travel or rotation, required power-loss behaviour and mounting dimensions.

Manufacturer information

HVAC sensors

NS8000 includes single- and multifunction network sensors for temperature, humidity, CO2 and occupancy. Measured quantities vary by part number; check the network and connected controller.

For selection: Full part number, measured quantities, mounting location, network or interface, supply and controller code.

Manufacturer information

Thermostats and room controllers

TEC3000 offers networked, wireless and standalone versions for applications including two- and four-pipe fan coils. Wiring and outputs must match the actual installation.

For selection: Full TEC code, equipment type, two- or four-pipe arrangement, control stages and outputs, voltage and BMS connection requirements.

Manufacturer information

PENN temperature and pressure controls

A421 is used with single-stage refrigeration or HVAC equipment. P77 handles a single pressure; P78 combines high- and low-pressure control. Setpoints, reset and electrical version depend on the full code.

For selection: Code, refrigerant or medium, range, setpoints, differential, reset type, voltage and contact load, sensor or capillary.

Manufacturer information

Manufacturer information ↗

YORK air-cooled chillers

The current Johnson Controls commercial catalog includes variable-speed screw YVAA and scroll YLAA chillers. These commercial lines do not establish ownership of all residential YORK products.

For selection: Model and serial number, design cooling capacity, fluid and ambient temperatures, refrigerant and power supply; component code and diagram position for parts.

Manufacturer information

YORK water-cooled chillers

The current catalog includes centrifugal YK and magnetic-bearing centrifugal YZ/YMC2 chillers. Similar applications do not make compressor or control components interchangeable.

For selection: Model, serial number, refrigerant, evaporator and condenser conditions, supply; documented part number and component nameplate for replacement.

Manufacturer information

Information for equipment selection

Describe the site, system duty, required capacity and design conditions. Attach a specification or diagram. Controls require supply voltage, signals, network and connected devices; equipment requires medium, temperatures and installation constraints.

Spare parts, actuators and control components

Send the full part number, quantity, nameplate photo and drawing position. Boards and controllers require version, firmware and configuration; valves and actuators require connection details, characteristics and control signal. Replacement suitability is checked against the exact-version documentation.

Send a project, model or parts list

Include quantity and delivery location. Attach a specification, marking photo or wiring diagram.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.