Industrial Transformers & Reactors Bi-mec Trasformatori (Bi-mec S.r.l.)
Italian-made dry-type single-phase and three-phase transformers, medical isolating units, autotransformers, current transformers, and inverter reactors by Bi-mec Trasformatori (Bi-mec S.r.l.) built to project specs.
Custom Transformers T1B–T6B
Custom single-phase and three-phase transformers built to client electrical and dimensional specs with permanent coding. TB1 (30–3,000 VA), T2B, and T3B (Dyn11) operate in continuous duty. Resin-encapsulated T4B, T5B, and split-core T6B serve PCB electronics.
- TB1 / T2B / T3B: from 30 VA, IP00, 4 kV / 50 Hz
- T4B / T5B / T6B: PCB resin-encapsulated, 3 kV
- Insulation class F (A, B, E, H on request)
- Permanent individual code for reproduction
Three-Phase T3F, T3N & T3 ULA Series
Standard T3F three-phase transformers span 0.050 to 225 kVA with Dyn11 displacement and 400 V input to 230 V output. Eco series T3N (4 to 30 kVA) cuts losses and limits inrush current to 5x rated current. T3 ULA integrates UL-listed insulation for North America.
- T3F: 0.050–225 kVA, Dyn11, IP20, 3 kV / 50 Hz
- T3N Eco: 4–30 kVA, low loss, 5x inrush current
- T3 ULA: UL-listed insulation system (XPTQ2/8)
- Frequency 50/60 Hz, Class I protection, Class F
Medical Isolating T1M, T2M & T3M
Single-phase (T1M, T2M) and three-phase (T3M) isolating transformers built to CEI EN 61558-2-15 for medical locations. Double or reinforced insulation pairs with an electrostatic shield between primary and secondary. Integrated PT100 probes support optional thermal monitors.
- CEI EN 61558-2-15, dielectric strength 5 kV / 50 Hz
- Input up to 1,000 V AC, output max 250 V AC
- Primary-secondary shield and PT100 temperature probes
- Inrush current 12x, Ynyn0 vector group (T3M), IP20
Single-Phase T1F, T1D, T1C, T2F & TOR
Compact safety and isolating transformers for control panels span from 20 VA (T1C with 6.3 mm Faston lugs) to 25 kVA (T2F). T1D units (40–500 VA) add an IP21 enclosure for DIN-rail or screw mounting. Toroidal TOR units cover up to 600 V with Class II protection.
- T1C: 20–120 VA, IP20, 6.3 mm Faston terminals
- T1D: 40–500 VA, IP21 enclosure, Class II, DIN rail
- T1F (30 VA–4 kVA) & T2F (3.5–25 kVA), 400/230 V
- TOR toroidal: up to 600 V, 4 kV dielectric, Class II
Autotransformers A1F, A2F, A3F & T1 ULC
Single-phase and three-phase autotransformers under CEI EN 61558-2-13 serve installations where galvanic separation is unnecessary. A shared winding reduces footprint and weight based on equivalent power Pn. T1 ULC and T3 ULA variants meet UL insulation requirements.
- A1F, A2F & A3F built per CEI EN 61558-2-13
- Sizing formula: Pn = ((Vmax - Vmin) / Vmax) x VA
- T1 ULC & T3 ULA with UL-listed insulation systems
- Compact single-winding construction for 50/60 Hz
Amperometric Transformers TA1–TA5
Current transformers across the TA1, TA2, TA3, TA4, and TA5 series measure line current inside industrial switchboards. Pass-through windows accommodate power cables or copper busbars with DIN-rail mounting options. Secondary terminals include IP20 protective covers.
- Five standard frame sizes: TA1, TA2, TA3, TA4, TA5
- Pass-through aperture for cables or copper busbars
- DIN-rail mounting with IP20 secondary terminal cover
- Designed for industrial switchgear and metering
Line, Drive & Starter Reactors
Three-phase R3L line reactors (1.5–830 kW, 400 V, 4% impedance) mount upstream of inverters, while R3I motor reactors (10–100 Hz, 3 kHz PWM) damp dv/dt and cable currents downstream. RAM reactors handle asynchronous motor soft starting at 70% torque. Air-core and PFC reactors also ship.
- R3L / R3I: 1.5–830 kW, 400 V AC, 4%, EN 60289
- R3I motor side: 3 kHz PWM, 10–100 Hz rating
- RAM starter: 70% static torque, 4 starts/hour
- Saturation 1.5 x In, Class F, IP00/IP20 options
Transformer Boxes T2/T3 & Protection Parts
T2 box and T3 box steel enclosures protect transformers in standard IP23 RAL 7035 or custom IP54/IP55 ratings. Housings integrate lifting eye bolts, pallet-truck bases, optional wall-mounted junction boxes, and hot-air exhaust fans. Protective fuses and thermal switches complete panel builds.
- T2 / T3 box: standard IP23 RAL 7035, IP54/IP55 custom
- Lifting eye bolts and pallet-truck base integrated
- Optional cooling ventilation fans and junction boxes
- Fuses, 115 C thermal links, 80 C bimetal, PTC limiters
Bi-mec Trasformatori Product Architecture & Series Matrix
Bi-mec Trasformatori (Bi-mec S.r.l.) produces custom B-series (T1B–T6B), standard single-phase and three-phase transformers from 20 VA to 225 kVA (T1F, T1D, T2F, T3F, T3N, medical T1M/T3M), A1F–A3F autotransformers, TA1–TA5 current transformers, R3L/R3I/RAM reactors up to 830 kW, and T2/T3 boxes.
Every unit is manufactured in-house in Altavilla Vicentina, Italy—from automatic coil winding and copper/aluminum flat-strip winding to core assembly, impregnation, resin finishing, and ISO final testing with a factory test report.
Each unit carries a permanent individual code for exact future reproduction.
Selecting Isolating Units, Autotransformers & Inverter Reactors
Standard isolating series T1F, T1D (IP21 DIN-rail), T2F (3.5–25 kVA), T3F (0.050–225 kVA, Dyn11), and low-loss T3N (4–30 kVA, 5x inrush) provide galvanic separation tested at 3–4 kV for 60 s. Medical locations specify T1M, T2M, and T3M per CEI EN 61558-2-15 with 5 kV dielectric strength, shielding, and PT100 sensors.
When galvanic separation is not required, A1F–A3F autotransformers per CEI EN 61558-2-13 save panel space via Pn = ((Vmax - Vmin) / Vmax) x VA.
Variable frequency drives pair R3L line reactors (400 V, 4% impedance) upstream and R3I motor reactors (10–100 Hz, 3 kHz PWM) downstream, while RAM units support motor soft starts.
Thermal Derating, UL Insulation Systems & Protective Enclosures
Bi-mec insulation classes span A (105 C), E (120 C), B (130 C), F (155 C), and H (180 C) rated at ta 40 C ambient temperature. Higher ambient environments require derating nominal output by -15% at 50 C, -30% at 60 C, and -40% at 70 C.
Export panels for North America specify T1 ULC and T3 ULA with UL-listed insulation systems. Open IP00/IP20 assemblies can be housed in steel T2 box or T3 box enclosures in standard IP23 RAL 7035 or IP54/IP55 finishes with lifting eye bolts, junction boxes, and cooling fans.
Bi-mec Trasformatori and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Bi-mec Trasformatori and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Bharat Bijlee
- Equipment and parts for BGS General
- Equipment and parts for BEYER Maschinenbau
- Equipment and parts for Bevini S.r.l.
Documents and sources
- Bi-mec Trasformatori — Company and permanent coding
- Bi-mec Trasformatori — Manufacturing and final testing
- Bi-mec Trasformatori — Standards, insulation classes and thermal derating
- Bi-mec Trasformatori — Custom B-series transformers
- Bi-mec Trasformatori — TB1 single-phase custom series
- Bi-mec Trasformatori — T2B single-phase custom series
- Bi-mec Trasformatori — T3B three-phase custom series
- Bi-mec Trasformatori — T4B resin-encapsulated PCB transformers
- Bi-mec Trasformatori — T5B PCB dry-type transformers
- Bi-mec Trasformatori — T6B low-profile split-core transformers
- Bi-mec Trasformatori — Standard transformers catalogue
- Bi-mec Trasformatori — T3F three-phase series (0.050–225 kVA)
- Bi-mec Trasformatori — T3N Eco low-inrush series (4–30 kVA)
- Bi-mec Trasformatori — T3M three-phase medical series
- Bi-mec Trasformatori — T1M single-phase medical series
- Bi-mec Trasformatori — T2F single-phase series (3.5–25 kVA)
- Bi-mec Trasformatori — T1D IP21 DIN-rail series
- Bi-mec Trasformatori — T1C Faston 6.3 mm series (20–120 VA)
- Bi-mec Trasformatori — TOR toroidal series up to 600 V
- Bi-mec Trasformatori — A1F autotransformer series
- Bi-mec Trasformatori — Industrial reactors catalogue
- Bi-mec Trasformatori — R3L three-phase line reactors
- Bi-mec Trasformatori — R3I three-phase motor drive reactors
- Bi-mec Trasformatori — RAM motor starter reactors
- Bi-mec Trasformatori — T2 box and T3 box enclosures