Beta Electronics / Atex Beta Temperature Controllers & Automation

Italian industrial and refrigeration temperature controllers by Beta Electronics / Atex Beta (ATEX Industries / Xetup): panel-mount and DIN-rail RC31, RC33, RC34, DC32, RD41, BL43, GR42, and RC43-III controllers with NTC/PTC/PT1000 probes.

Beta RC31 II Controllers for Static Units

The RC31 II Series provides single-relay ON/OFF regulation (16 A SPST or 8 A SPDT) for static cooling or heating units with NTC/PTC/PT1000 probe input, HACCP event logging, and a TTL Modbus port. Supply options cover 230 Vac, 115 Vac, and 9–24 Vac/dc.

  • 1 relay: 16 A SPST or 8 A SPDT
  • NTC, PTC, or PT1000 input (0.1 °C)
  • Supply 230/115 Vac or 9–24 Vac/dc
  • TTL Modbus port and 3-event HACCP

Beta RC33 II & RC34 Ventilated Unit Controllers

RC33 II and RC34 controllers manage ventilated positive and sub-zero refrigeration systems with dual NTC/PTC inputs for cabinet and evaporator. Outputs drive compressor (16 A), defrost heater (8 A), and fan (5 A) loads. Electrical and hot-gas defrost cycles are supported via TTL Modbus.

  • Relays: 16 A comp, 8 A defrost, 5 A fan
  • 2 analog inputs: NTC or PTC probes
  • Time or evaporator-temp defrost end
  • Digital switch input & TTL Modbus

Beta DC32 II Dual-Zone & Dead-Band Controllers

The DC32 features two configurable relays (SPDT 8 A + SPST 16 A) for neutral-zone operation or two independent temperature setpoints. It accepts one or two NTC/PTC probes plus a digital input. Built-in diagnostics flag probe faults (PF1/PF2), low voltage (LoV), and memory errors (EEP).

  • 2 relays: SPDT 8 A + SPST 16 A
  • Neutral-zone or 2-stage control
  • NTC (-40..+120 °C) / PTC (-50..+150 °C)
  • Fault codes PF1, PF2, LoV & EEP

Beta RD41 Single-Point Electronic Thermostats

The RD41 (Red Line Series) is a single-intervention-point electronic thermostat for cooling and heating electrical panels. It covers -55 to +270 °C with 1 PTC probe input. Parameters Act, HYS, AcY, and OFS configure cooling/heating action, hysteresis, anticycling, and probe offset.

  • Measuring range -55 to +270 °C
  • 1 PTC temperature probe input
  • Heat/cool mode (Act) & AcY timer
  • Probe offset calibration OFS ±9.9 °C

Beta BL43 Sub-Zero Refrigeration Controllers

The BL43 controller is engineered for electrical control panels on sub-zero ventilated refrigeration equipment. Operating across -55 to +55 °C with 2 PTC probes, it coordinates compressor cooling, defrost cycles, and evaporator fan logic in commercial and industrial freezers.

  • Range -55 to +55 °C for sub-zero units
  • 2 PTC probe inputs
  • Built for ventilated freezer systems
  • Control-panel electrical integration

Beta GR42-8 & GR42-9 Two-Point Controllers

GR42-8 and GR42-9 provide independent two-point cooling and heating regulation across -50 to +150 °C with ±0.5 °C accuracy using PTC probes. Up to three relays handle main loads (8 A / opt. 16 A SPDT) and alarms (5 A SPST). The UL94V0 housing delivers IP64 front-panel protection.

  • Range -50 to +150 °C, ±0.5 °C accuracy
  • 2 SPDT 8 A (opt. 16 A) + 5 A alarm
  • Supply 12/24 Vac/dc, 115 or 230 Vac
  • IP64 front panel, UL94V0 enclosure

Beta RC43-III Modular DIN-4 Controllers

The RC43-III (BT91023426 / BT91023100) mounts on a 4-module omega DIN rail with 3 configurable NTC/PTC/PT1000 inputs up to +350 °C, 5 relays up to 16 A, RS-485 Modbus, USB, and 2.4 GHz Wi-Fi. Each relay maps independently to probes for cooling, heating, or dead-band control.

  • 4-module Omega DIN rail, 230 Vac ±10%
  • 3 probes: NTC 10K/5K, PTC, PT1000 (+350 °C)
  • 5 relays: 16 A SPST/SPDT, 8 A, 2×5 A
  • RS-485 Modbus, USB & 2.4 GHz Wi-Fi

Temperature Probes (NTC/PTC/PT1000) & Communication Modules

Service replacements for Beta Electronics / Atex Beta systems include NTC 5K/10K (-40 to +120 °C), PTC (-50 to +150 °C), and PT1000 (-50 to +350 °C) probes. Panel maintenance also covers power relays (16 A / 8 A / 5 A), 2.5 mm² terminal blocks, and TTL-to-RS485 or Wi-Fi adapters.

  • NTC 5K/10K, PTC & PT1000 probes
  • TTL Modbus, RS-485 & Wi-Fi modules
  • 2.5 mm² gauge terminal block connectors
  • Replaceable relay & power subassemblies

Panel-Mount vs. DIN-Rail Architecture

Beta Electronics / Atex Beta RC31, RC33, RC34, DC32, and GR42 controllers install directly into machine front cutouts with sealed waterproof displays (up to IP64 front protection on GR42 series).

RD41, BL43, and RC43-III units mount inside electrical cabinets on standard DIN rails, with RC43-III occupying a 4-module omega DIN footprint and accepting 2.5 mm² terminal wiring.

Power Supply, Probe Selection & Connectivity

Specify supply voltage (230 Vac, 115 Vac, or 9–24 Vac/dc), relay count (1 to 5 outputs rated up to 16 A), and sensor configuration before ordering equipment or replacements.

RC43-III (BT91023426 / BT91023100) supports 3 configurable NTC/PTC/PT1000 inputs up to +350 °C alongside USB data transfer, RS-485 Modbus wired bus, and 2.4 GHz Wi-Fi.

Beta Electronics and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Beta Electronics and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.