UTENTRA Industrial Fans
Italian centrifugal, axial, and roof fans, smoke exhausters, and replacement impellers by UTENTRA for industrial ventilation, dust extraction, and pneumatic conveying.
Centrifugal fans U/HC, U/AR, U/ARP, and U/AP
UTENTRA U/HC, U/AR, U/ARP, and U/AP centrifugal fans move clean or slightly dusty air and fumes up to 80 °C (HT up to 250 °C). Statically and dynamically balanced forward-curved impellers mount directly to 2- or 4-pole UNEL-IEC motors with optional TR belt drive.
- Fluid up to 80 °C (HT version 250 °C)
- 45° scroll orientation (RD or LG)
- B3/B5 IP55 UNEL-IEC motors, 50/60 Hz
- Parts: impellers, motors, SF/SI valves
Backward-curved fans U/CB, U/PB, U/PBM, and U/MPR
UTENTRA U/CB, U/PB, U/PBM, and U/MPR centrifugal fans use statically and dynamically balanced backward-curved steel sheet impellers for high flow rates and medium-to-high industrial pressures. U/PB models convey solid particles mixed with air up to 80 °C.
- Backward-curved balanced steel impellers
- AISI 304 (AI) & NV105 anti-spark (AS)
- B3 IP55 2/4-pole motors, TR 9/12 drive
- Parts: rotors, GA/GM joints, SD/SF dampers
High-pressure & conveying fans U/TM, U/RF, U/APE, and U/HPG
UTENTRA U/TM and U/RF fans feature open blades to prevent clogging with granulates or shavings. Replaceable impellers, IP55 UNEL-IEC motors, and FL filters match exact series, RD/LG rotation, and discharge angle. U/APE and reinforced U/HPG deliver high pressure.
- Open-blade impellers prevent clogging
- Profile-reinforced U/HPG spiral body
- 2-pole B3 IP55 motors up to 80/250 °C
- Parts: open impellers, SA/SM silencers
Double-inlet U/DS & motor-cooling U/HF fans
UTENTRA U/DS double-inlet fans (142 and 202 with one double-intake wheel; 162 and 182 with two single wheels, IP54) provide rapid forced ventilation up to 80 °C. U/HF fans mount directly on electric motors with an FL inlet filter and LG rotation.
- U/DS 142/202 & dual-wheel 162/182 IP54
- U/HF motor cooling with FL inlet filter
- 60 Hz (HZ) and tropical (TH) versions
- Parts: FL filter, RP guard, RF/CA flanges
Industrial axial fans U/EL, U/EP, and U/EI-EIL
UTENTRA U/EL square-frame, U/EP bracketed, and U/EI-EIL double-flanged axial fans move high air volumes up to 50 °C with IP55 B5 or B3 motors. U/EI aluminum-alloy airfoil blades allow standstill pitch adjustment from Ø 710 mm and support reversible airflow.
- Airflow temperature up to 50 °C
- Reversible flow (except U/EL 253/303)
- Adjustable blade pitch from Ø 710 mm
- Parts: 6-blade wheel, SG gravity shutter
Roof fans U/ET, U/CT, and smoke exhausters U/AT
UTENTRA U/ET axial roof extractors operate up to 50 °C with weatherproof powder-coated steel hoods, while U/CT centrifugal roof fans use backward blades up to 80 °C (HT 250 °C). U/AT radial-blade chimney smoke exhausters handle 250 °C fumes with an extra cooling impeller.
- U/ET weatherproof axial roof up to 50 °C
- U/CT centrifugal roof (HT up to 250 °C)
- U/AT 250 °C chimney draught exhauster
- Parts: cooling impeller, PG shutter, net
Selecting fan geometry by airstream, dust load, and temperature
Clean or lightly dusty air up to 80 °C suits forward-curved U/HC, U/AR, U/ARP, and U/AP units or high-efficiency backward-curved U/CB models. Heavy dust, granulates, and wood or metal shavings require open-blade U/TM and U/RF impellers or reinforced U/PB and U/HPG fans.
High-temperature exhaust up to 250 °C is handled by U/AT radial-blade chimney exhausters or HT variants built with an extended shaft and auxiliary cooling impeller.
Motor standards, special builds, and matching accessories
Most centrifugal and axial lines install UNEL-IEC self-ventilated asynchronous motors (IP55, B3 or B5; IP54 on U/DS double-inlet fans), with 60 Hz (HZ) and TR belt-drive arrangements (9 or 12) available.
Scroll housings orient in 45° steps for clockwise (RD) or counter-clockwise (LG) rotation, and options include AISI 304 stainless steel (AI), ANIMA-COAER NV105 anti-spark builds (AS), tropical insulation (TH), FL filters, SA/SM silencers, and SF/SI/SD dampers.
UTENTRA and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of UTENTRA and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for T.G.E. VENTILATORI
- Equipment and parts for ZIEHL-ABEGG
- Equipment and parts for T.G. FILTER
- Equipment and parts for T-T ELECTRIC
Documents and sources
- UTENTRA company profile (over 60 years experience)
- UTENTRA factory location in Rovellasca, Italy
- Centrifugal fans Series U/HC
- Centrifugal fans Series U/AR
- Centrifugal fans Series U/CB
- Centrifugal fans Series U/PB
- Pneumatic conveying fans Series U/TM
- High-pressure fans Series U/APE
- Reinforced high-pressure fans Series U/HPG
- Double inlet fans Series U/DS
- Motor cooling fans Series U/HF
- Axial fans Series U/EL
- Axial fans Series U/EP
- Ducted axial fans Series U/EI-EIL
- Axial roof fans Series U/ET
- Centrifugal roof fans Series U/CT
- Smoke exhaust fans Series U/AT (up to 250 °C)