UT99 AG Oil Mist Separators & Crankcase Ventilation

Swiss coalescing oil mist separators and crankcase or turbine lube oil tank ventilation systems from UT99 AG for power generation, marine and industrial plants.

UPF-CCV closed crankcase ventilation separators

The UPF-CCV series handles closed crankcase ventilation on gas, diesel and dual-fuel engines up to 32 MW and 1,000 m³/h blow-by flow with 99.9% separation down to 0.1 µm droplets. It prevents turbocharger coking and lifts gas efficiency by up to 0.7%. Units span UPF-CCV-15, 450 and 844.

  • Engine output: up to 32 MW
  • Blow-by flow: up to 1,000 m³/h
  • Residual oil: < 1 mg/m³ (0.1 mg/m³ opt.)
  • Pressure drop: < 20 mbar (8 mbar opt.)

UPF-OCV open crankcase ventilation separators

UPF-OCV open ventilation units serve marine and stationary engines up to 100 MW with regulated fans. Coalescing filters achieve 99.5% efficiency below 5 mg/m³ residual oil under TA Luft. Models UPF-OCV-500 and 844-X1M to X4M handle 1,400 m³/h with GL/RINA and ATEX.

  • Engines up to 100 MW, flow up to 1,400 m³/h
  • Efficiency 99.5%, residual oil < 5 mg/m³
  • GL and RINA type approval, optional ATEX
  • Cartridge intervals: up to 24,000–32,000 h

UPF-OTV turbine lube oil tank separators

UPF-OTV active coalescence separators maintain a steady 5 to 10 mbar underpressure on gas, steam and hydro turbine lube oil tanks up to 60 m³ and 1,050 m³/h. Integrated fans stop oil mist escape through labyrinth seals at 99% separation. Range covers UPF-OTV-500, 630 and 844 units.

  • Lube oil tank volume: up to 60 m³
  • Extraction flow: 100 to 1,050 m³/h
  • Underpressure: 5–10 mbar, < 20 mg/m³ oil
  • Models: UPF-OTV-500, 630 and 844-A1M..A3M

Compact UPF-SauKuL units and UPF housings

Compact UPF-SauKuL modules and UPF-15, 250, 450, 500, 630 and 844 housings serve smaller and mid-size engines up to 4,000 kW. Variants P1A and P3A handle closed CCV loops, while X1A through X3A-4M support open OCV venting. Custom OEM housing assemblies and cartridges are available.

  • Engine range: ≤ 500 kW up to 4,000 kW
  • Blow-by capacity: 15 to 120 m³/h
  • CCV / OCV types: P1A–P3A and X1A–X3A-4M
  • UPF housings: 15, 250, 450, 500, 630 and 844

EPR pressure regulators and blow-by monitoring

Electronic pressure regulators (EPR) maintain optimal crankcase pressure in CCV systems and prevent engine shutdowns or oil leaks. Paired with blow-by volume flow measurement, they support condition monitoring at high gas temperatures and pulsations. Spare valves and sensors are matched.

  • Role: active crankcase pressure stabilization
  • Function: blow-by volume flow measurement
  • Components: throttle valve, actuator, sensors
  • Benefit: leak prevention and wear diagnostics

Legacy Dynapure replacement and UPF retrofit

The current UPF platform replaces the discontinued Dynapure series, including models UF-AS-100, UF-AS-200, UF-AS-500, UF-AS-700 and CH310. Modular UPF housings enable cost-effective power plant retrofits with full control system integration. Conversion assemblies and filters are matched.

  • Supersedes Dynapure UF-AS-100/200/500/700
  • Direct UPF upgrade path for legacy CH310
  • Control-system integration for plant retrofits
  • Matched mounting adapters and filter cartridges

Selecting between UPF-CCV, UPF-OCV and UPF-OTV

UPF-CCV units serve closed crankcase ventilation on gas, diesel and dual-fuel engines up to 32 MW, returning filtered blow-by gas with < 1 mg/m³ oil to protect turbochargers and improve gas engine efficiency by up to 0.7%.

UPF-OCV fan-assisted units handle open ventilation up to 100 MW below 5 mg/m³ TA Luft limits, while UPF-OTV separators maintain 5–10 mbar underpressure on gas, steam and hydro turbine lube oil tanks up to 60 m³.

Coalescing filter life and Dynapure retrofit

Multi-stage coalescing cartridges capture 0.1 µm oil droplets with pressure drop below 20 mbar (8 mbar optional), delivering service intervals up to 16,000 h on CCV and 24,000–32,000 h on OCV/OTV.

The UPF platform supersedes discontinued Dynapure units (UF-AS-100, UF-AS-200, UF-AS-500, UF-AS-700, CH310), allowing straightforward mechanical and control-system retrofits.

Swiss engineering, DIN 5167 testing and OEM partners

Founded on IPTC AG (1947) with environmental filtration since 1969 and based in Andelfingen, Switzerland (Storskogen Schweiz AG group), UT99 AG operates under ISO 9001:2015 and tests every unit on a DIN 5167 rig.

Separators are deployed across engines and power plants from 2G Energy, Caterpillar Energy Solutions, MAN / Everllence, Wärtsilä, MTU Friedrichshafen, GE Power, Weichai and Yuchai, with optional GL, RINA and ATEX executions.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.