Talema (Etal Group) Toroidal Transformers & Magnetics

Toroidal power transformers (1 VA – 7.5 kVA), UL/IEC 60601-1 medical isolation units, IEC 61869-2 current transformers, EMC chokes, and custom magnetic assemblies from Talema (Etal Group).

Toroidal Power Transformers (1 VA – 7.5 kVA)

Talema (now unified under Etal Group) toroidal power transformers are built with continuous-strip virgin grain-oriented silicon steel cores and copper windings from 1 VA to 7.5 kVA per phase. Stock 15 VA–1 kVA units operate at 48–450 Hz with 4500 VAC isolation and DIN 35 mounts.

  • Power: 1 VA – 7.5 kVA per phase
  • Primary: 230 V or 2×115 V, 48–450 Hz
  • 4500 VAC dielectric flash test
  • Mounts: center potting, Polyamid, DIN 35

Encapsulated PCB Toroids (70000, 72400, 6400K, 6500K)

Talema (Etal Group) encapsulated PCB toroidal transformers cover 1 VA to 160 VA for compact power electronics. Low-profile 70000 and 72400 series (1.6–50 VA, dual 115/120 V) and high-power 6400K/6500K series (up to 160 VA, 115/230 V) feature 4.0 kV dielectric testing and Class A/E insulation.

  • 70000 & 72400 Series: 1.6 – 50 VA
  • 6400K & 6500K Series: up to 160 VA
  • 4.0 kV primary-secondary test
  • Insulation: Class A 105 °C / E 125 °C

Medical Grade Isolation Transformers (IEC / UL 60601-1)

Talema and Etal Group medical isolation transformers handle 240/120/100 V and 240/120 V mains up to 3000 VA and 15 kVA. Engineered to UL 60601-1 and IEC 60601-1 with 2xMOPP reinforced insulation, 4 kVAC testing, thermal protection, and low leakage current for medical systems.

  • Ratings: up to 3000 VA and 15 kVA
  • 2xMOPP per UL/IEC 60601-1
  • 4 kVAC reinforced insulation test
  • Built-in thermal cut-out protection

Measurement & Protection Current Transformers (IEC 61869-2)

Talema (Etal Group) toroidal current transformers are engineered and tested to IEC 61869-2:2012 for industrial metering, overload monitoring, and protection relays. Standard and custom CTs feature single-turn or multi-turn primaries, low phase error, and calibrated secondary burden termination.

  • Compliant with IEC 61869-2:2012
  • Low phase displacement & ratio error
  • Precision burden resistor scaling
  • Metering, relays & overload control

Inductors, Chokes & Reactors (EMC, PF & SMPS)

Talema and Etal Group inductive components cover common mode chokes, EMC/EMI suppression chokes, PF chokes, saturable reactors, and AC/DC smoothing chokes. Distributed iron-powder and multi-gapped cores stabilize inductance, lower fringing losses, and suppress harmonics in power converters.

  • Common mode & EMI suppression chokes
  • SMPS flyback & coupled inductors
  • PF, smoothing & saturable reactors
  • Gapped & iron powder core designs

High-Frequency SMPS, Planar, Power (1 MVA) & Custom Assemblies

Etal and Talema manufacture ferrite SMPS transformers (kHz to MHz) for CNC and inverters, sealed planar units, auto, 70V/100V audio, HV, and 1 kVA–1 MVA power transformers. Special assemblies add Faston terminals, wiring looms, and thermistors from 1 to 1000+ units.

  • SMPS (kHz–MHz) & sealed planar coils
  • 1 kVA – 1 MVA power, HV & 3-phase
  • Custom looms, Faston & thermistors
  • Batches from 1 unit to 1000+ units

Talema Integration into Etal Group & Core Engineering Advantages

Talema (including Nuvotem Talema and NT Magnetics) now operates under the unified Etal Group brand within KAMIC Group’s Etalema business area.

Standard Talema series (70000, 72400, 6400K, 6500K, and 15 VA–1 kVA EN61558 stock toroids) remain integral to industrial power, medical instrumentation, and automation equipment.

Continuous-strip virgin grain-oriented silicon steel toroidal cores eliminate air gaps and loose laminations, reducing stray magnetic fields, audible hum, and footprint by roughly half compared to conventional laminated designs.

OEM Specification Checklist & Custom Assemblies

When preparing an RFQ for OEM equipment or replacement assemblies, specify apparent power (VA or kVA), primary/secondary voltages, operating frequency (48–60 Hz, up to 450 Hz, or high-frequency kHz–MHz SMPS), dielectric strength (4.0–4.5 kVAC), and mounting format (center potting, Polyamid enclosure, PCB, or DIN 35 rail).

For medical devices (UL/IEC 60601-1 up to 3000 VA and 15 kVA) include 2xMOPP isolation and thermal cut-out options; for IEC 61869-2 current transformers specify transformation ratio and secondary burden resistance. Special assemblies are manufactured from 1 unit to 1000+ units.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.