DECTRIS Hybrid-Pixel X-Ray & Electron Detectors
Swiss-engineered DECTRIS hybrid-pixel and charge-integrating X-ray detectors (PILATUS4, EIGER2, MYTHEN2, SELUN, POLLUX, JUNGFRAU) and direct electron detectors (ARINA, ELA, QUADRO, SINGLA) for laboratories, synchrotrons, and TEM.
DECTRIS PILATUS4 (R, X, XE) 2D Photon-Counting Detectors
PILATUS4 R, X, and XE 2D X-ray detectors combine a 150 um pixel pitch, four energy thresholds, and >95% quantum efficiency at up to 4,000 Hz. Si (6-40 keV) and CdTe (8-100 keV) sensors serve XRD and SAXS beamlines and labs. Spares include sensor modules, windows, and DCU servers.
- 150 x 150 um pixel, 4 thresholds
- Si 450 um (6-40 keV), CdTe (8-100 keV)
- Up to 4,000 Hz, >10^7 ph/s/pixel
- Modules, vacuum windows, DCU units
DECTRIS EIGER2 (R, S, X, XE, CdTe) X-Ray Detectors
EIGER2 R, S, X, and XE detectors offer 75 um pixels, dual energy thresholds, and formats from 250K to 16M plus wide 1M-W/2M-W arrays. Si (5.4-40 keV) and CdTe (8-100 keV) sensors reach 4,500 Hz with <100 ns dead time. Spares cover modules, cooling loops, and EPU servers.
- 75 x 75 um pixel, 250K to 16M arrays
- Up to 4,500 Hz, <100 ns dead time
- Si 450 um and CdTe 750 um (8-100 keV)
- Detector modules, chillers, EPU units
DECTRIS MYTHEN2 (R, X) 1D Microstrip X-Ray Detectors
MYTHEN2 R and X 1D microstrip detectors feature a 50 um strip pitch (640 or 1,280 strips), 89 us readout, and Si sensors from 4 to 40 keV. The DCS4 control system synchronizes multimodular arrays up to 1,000 Hz. Spares include strip modules, DCS4 electronics, cables, and flanges.
- 50 um strip width, 640 / 1,280 strips
- 89 us readout, Si 320/450/1,000 um
- 100 Hz (R) and 1,000 Hz (X with DCS4)
- Strip modules, DCS4 units, vacuum seals
DECTRIS SELUN, POLLUX & JUNGFRAU X-Ray Detectors
SELUN (Si and 1,500 um CZT) achieves 120 kHz continuous framing above 4.5 G ph/s/mm2, compact air-cooled POLLUX (<600 eV @8 keV, 360 Hz) suppresses fluorescence, and charge-integrating JUNGFRAU (4 MP, 2,000 Hz) avoids saturation. Spares cover readout boards, windows, and cooling.
- SELUN: 120 kHz (2x2), Si / CZT 1,500 um
- POLLUX / PANORAMA HR: 360 Hz, <600 eV
- JUNGFRAU: 4 MP 75 um, 2,000 Hz liquid
- Readout boards, windows, coolant lines
DECTRIS ARINA, ELA, QUADRO & SINGLA Electron Detectors
For TEM/STEM, DECTRIS offers retractable ARINA (120,000 fps for 4D-STEM), post-spectrometer ELA for EELS (up to 18,000 Hz ROI), retractable QUADRO for microED, and bottom-mounted SINGLA (30-200 keV, DQE(0) up to 0.98) for cryoEM. Spares cover retractors, TEM adapters, and PSUs.
- ARINA: 192x192 100 um, 120,000 fps STEM
- ELA: 1028x512 75 um EELS / 4D-STEM
- QUADRO: 510x510 retractable microED
- SINGLA: cryoEM 30-200 keV, DQE(0) 0.98
DECTRIS Processing Units (EPU, PPU, DCU) & Specific Solutions
Linux-based EPU, PPU, and DCU servers buffer and stream data from PILATUS4, PILATUS3, EIGER2, and SELUN via SIMPLON API, ALBULA, and NOVENA. Specific Solutions builds custom vacuum and windowless detectors down to 1.6 keV. Spares include servers, optical links, and feedthroughs.
- EPU, PPU & 1-rack-mounted DCU servers
- SIMPLON API, HDF5/NeXus, FURKA2/GRIMSEL2
- Custom in-vacuum arrays down to 1.6 keV
- Server nodes, optical links, feedthroughs
Selecting DECTRIS X-Ray Detectors: PILATUS4, EIGER2, MYTHEN2, SELUN & POLLUX
For X-ray diffraction and scattering, buyers select PILATUS4 (150 um pixel, 4 thresholds), EIGER2 (75 um pixel, up to 4,500 Hz), 1D microstrip MYTHEN2 (50 um), 120 kHz SELUN, compact POLLUX, or charge-integrating JUNGFRAU detectors.
Silicon sensors (450 um Si) cover 5.4-40 keV laboratory and synchrotron lines (Cu, Cr, Co), whereas 750-1,000 um CdTe and 1,500 um CZT sensors deliver high quantum efficiency for Mo, Ag, In, and hard X-ray beamlines up to 100 keV.
Selecting DECTRIS Electron Detectors for TEM: ARINA, ELA, QUADRO & SINGLA
For transmission electron microscopy, DECTRIS supplies retractable ARINA (120,000 fps for 4D-STEM), post-spectrometer ELA for EELS, retractable QUADRO for microED, and bottom-mounted SINGLA (30-200 keV) for cryoEM.
Direct single-electron counting eliminates readout noise and dark current, enabling low-dose structural characterization of organic crystals, MOFs, battery materials, and biological specimens on JEOL, Thermo Fisher Scientific, Nion, and TESCAN platforms.
Processing Units (EPU, PPU, DCU), Software & Specific Solutions
Linux-based EPU, PPU, and rack-mounted DCU hardware buffer continuous data streams up to 18 GB/s through SIMPLON API, ZMQ streaming, HDF5/NeXus output, and ALBULA / NOVENA / XDS data analysis tools.
DECTRIS Specific Solutions engineers custom planar or curved vacuum-compatible detector geometries with removable windows and energy calibrations down to 1.6 keV for simultaneous SAXS/WAXS, plasma spectroscopy, and OEM diffractometers.
DECTRIS and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of DECTRIS and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for TESCAN
- Equipment and parts for Viscom
- Equipment and parts for Oxford Lasers
- Equipment and parts for Nanoscribe
- Equipment and parts for Tabor Electronics
Documents and sources
- DECTRIS AG history — founding in Switzerland in 2006 and product milestones
- PILATUS4 R for Laboratories — Si and CdTe specifications
- PILATUS4 X/XE for Synchrotrons — up to 4,000 Hz and SIMPLON API
- EIGER2 R for Laboratories — 75 um pixel and 250K to 4M models
- EIGER2 R CdTe for Laboratories — Mo, Ag, In and up to 100 keV
- EIGER2 X/XE for Synchrotrons — Si arrays up to 16M
- EIGER2 X/XE CdTe for Synchrotrons — hard X-ray up to 100 keV
- MYTHEN2 R for Laboratories — 50 um strip detector specs
- MYTHEN2 X for Synchrotrons — 1,000 Hz and DCS4 controller
- SELUN and SELUN High-Z — 120 kHz coherent scattering detector
- POLLUX, PANORAMA and PANORAMA HR — dual-threshold lab detectors
- JUNGFRAU charge-integrating 4 MP detector — 2,000 Hz specifications
- ARINA retractable electron detector for 4D-STEM (120,000 fps)
- ELA hybrid-pixel electron detector for EELS and 4D-STEM
- QUADRO large-area retractable electron detector for microED and 4D-STEM
- SINGLA electron detector for cryoEM and microED (30-200 keV)
- Detector Data Processing — EPU, PPU, DCU hardware and D.LAB
- DECTRIS Support — hardware, software, commissioning, and repairs
- DECTRIS Product Life Cycle — five-year post-sale support policy
- DECTRIS Specific Solutions — custom vacuum and windowless detectors