J.A. Woollam Spectroscopic Ellipsometers — System Selection and Parts

Sourcing and configuration support for J.A. Woollam spectroscopic ellipsometers (RC2, M-2000, iSE, theta-SE, alpha 2.0, VASE, IR-VASE Mark II, VUV-VASE), automated mapping stages, and replacement light sources.

RC2 Ellipsometers

The RC2 dual rotating compensator ellipsometer (Dual RCE) collects all 16 Mueller matrix elements. Wavelength coverage spans 193-1000 or 210-1000 nm with +NIR/+xNIR options to 2500 nm. Serviceable modules include the dual light source, CCD detector, XY stages, and liquid cells.

  • Range: 193-2500 nm (+NIR/+xNIR)
  • Speed: 0.3 s minimum full spectrum
  • Incidence: 45-90 deg / 20-90 deg
  • Stages: XY to 300x300 mm, 4.2 K-1000 C

M-2000 Ellipsometers

The M-2000 rotating compensator ellipsometer (RCE) with CCD detection acquires over 700 wavelengths simultaneously from 0.05 seconds across ranges up to 193-1690 nm for in-situ ALD/CVD/MBE monitoring and 300x300 mm automated mapping.

  • Range: 193-1690 nm (D/X/U/V/+NIR)
  • Speed: 0.05 s min, 2-5 s typical
  • Detector: high-speed CCD array
  • Mounting: in-situ flange or XY stage

iSE In-Situ Ellipsometers

The iSE monitors thin film deposition and etching inside vacuum chambers in real time. Its Dual-Rotation CCD design covers 400-1000 nm across 190 wavelengths from 0.3 s. Core assemblies include the control box, tilt stage mounts, calibration base, and 2.75-inch optical viewports.

  • Range: 400-1000 nm (190 wavelengths)
  • Ports: 1.33 in or 2.75 in at 60-75 deg
  • Speed: 0.3 s min, ~3 mm beam size
  • Hardware: control box, viewports, base

theta-SE Mapping Ellipsometers

The theta-SE uses a patented dual-theta stage for automated 300 mm wafer mapping with a 250x600 um focused spot at 65 deg. Covering 400-1000 nm from 0.61 s, it integrates a quartz tungsten halogen (QTH) lamp, vacuum pump, alignment camera, RJ-45, and USB interfaces.

  • Mapping: 300 mm wafer dual-theta stage
  • Source: quartz tungsten halogen (QTH)
  • Spot: 250x600 um at 65 deg fixed angle
  • Built-in: vacuum pump, camera, PSU

alpha 2.0 Benchtop Ellipsometers

The alpha 2.0 is a compact benchtop dual-rotation ellipsometer for routine thickness and refractive index measurements on dielectrics, organics, a-Si, and metals. Covering 400-1000 nm at 65/70/75/90 deg, it handles samples up to 200 mm diameter and 16 mm thick.

  • Range: 400-1000 nm (190 wavelengths)
  • Sample size: up to 200 mm x 16 mm
  • Angles: 65, 70, 75, and 90 deg
  • Footprint: 20 x 13 x 12 in, 5-10 s scan

VASE Research Ellipsometers

The VASE pairs a rotating analyzer (RAE), patented AutoRetarder, and double-chamber monochromator across 193 to 4000 nm with 15-90 deg angles at 0.01 deg accuracy. Serviceable assemblies include the 75W xenon lamp, gratings, LN2-cooled InSb detector, and 100/200 um focusing optics.

  • Range: 240-2500 nm (193-4000 nm opt.)
  • Source: 75W convection-cooled xenon
  • Angles: 15-90 deg (0.01 deg accuracy)
  • Optics: AutoRetarder, 4-grating, InSb

IR-VASE Mark II Ellipsometers

The IR-VASE Mark II combines FTIR chemical sensitivity with spectroscopic ellipsometry from 1.7 to 30 um (333-5900 cm-1) at 1-64 cm-1 resolution for bond vibrations, phonons, and doping profiles. Replaceable components include the Globar source, scanning laser, DTGS detector, and stages.

  • Range: 1.7-30 um (333-5900 cm-1)
  • Detector: DTGS, 1-64 cm-1 resolution
  • Source: Globar IR source and laser
  • Angles: 32-90 deg, max substrate 20 mm

VUV-VASE Vacuum UV Ellipsometers

The VUV-VASE (Gen-I and Gen-II) spans 146-1100 nm (+xNIR to 2500 nm) for 157/193/248 nm lithography photoresists, GaN/AlN bandgaps, and fluorides. Key service items include deuterium and xenon lamps, monochromator optics, prism cells, and 140x140 mm XY or 300 mm R-theta stages.

  • Range: 146-1100 nm (+xNIR to 2500 nm)
  • Sources: deuterium + xenon lamps
  • Angles: 10-90 deg across VUV-NIR
  • Gen-II: 300 mm R-theta / 140x140 mm XY

Selecting an Ellipsometer Architecture by Application

For fast routine thickness and refractive index checks across 400-1000 nm, benchtop alpha 2.0 and automated 300 mm theta-SE mapping systems deliver streamlined recipes with CCD detection.

Complex anisotropic and depolarizing stacks require the RC2 dual rotating compensator (full 16-element Mueller matrix), while M-2000 and iSE provide sub-second in-situ process monitoring on ALD, CVD, PVD, and MBE chambers.

Extended VUV, UV-Vis-NIR and Mid-IR Research Systems

VASE and VUV-VASE platforms place a double-chamber scanning monochromator before the sample to protect photosensitive photoresists, reaching 146 nm in the vacuum UV for 193/157 nm lithography or up to 4000 nm with an LN2-cooled InSb detector.

IR-VASE Mark II spans 1.7-30 um (333-5900 cm-1) with a Globar source and DTGS detector to characterize molecular bond vibrations, epitaxial carrier concentrations, and phonon modes.

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.