Weiketory High-Pressure Preparative HPLC Systems & Fraction Collectors
In-house high-pressure preparative liquid chromatography systems WKPrep-10/50/100/300 (15-42 MPa, up to 300 mL/min), Collector V1 fraction collector, and CAD-coupled purification modules by Beijing WeikeTory (China).
High-pressure preparative HPLC system WKPrep-10 (42 MPa, 10 mL/min)
WKPrep-10 from Beijing WeikeTory scales analytical separations and purifies isomers on 4.6-10 mm columns. Its dual-pump binary gradient delivers up to 42 MPa and 10 mL/min at ±0.5% flow accuracy. Replaceable spares include SUS316L or PEEK pump heads, plunger seals, and check valves.
- Max pressure 42 MPa, flow 10 mL/min
- ±0.5% accuracy, 4.6-10 mm columns
- SUS316L, PEEK, Ti, Hastelloy, PTFE
- 5-inch touchscreen, RS232/RS485
Semi-preparative HPLC system WKPrep-50 (30 MPa, 50 mL/min)
WKPrep-50 handles high-purity isolation of peptides, saponins, and API impurities on 10-20 mm columns. It combines 30 MPa pressure and 50 mL/min flow at ±0.5% accuracy with a 190-400 nm UV detector. Spares cover deuterium UV lamps, flow cells, sapphire plungers, and seal kits.
- Max pressure 30 MPa, flow 50 mL/min
- ±0.5% accuracy, 10-20 mm columns
- Standard 190-400 nm UV detector
- Full-floating plunger seal design
In-house preparative HPLC system WKPrep-100 (20 MPa, 100 mL/min)
WKPrep-100 is an in-house high-pressure preparative HPLC platform delivering up to 100 mL/min at 20 MPa with ±1% flow accuracy for ~20 mm columns. It supports gram-scale purification of natural extracts and peptides. Spares cover SUS316L/PEEK pump heads, plunger seals, and check valves.
- In-house Beijing WeikeTory design
- 20 MPa pressure, up to 100 mL/min flow
- ±1% accuracy for ~20 mm prep columns
- Constant, dosing & gradient modes
High-throughput preparative HPLC system WKPrep-300 (15 MPa, 300 mL/min)
WKPrep-300 handles pilot-scale purification and bulk crude fractionation on 20-30 mm columns at up to 300 mL/min and 15 MPa. The modular 240×140×330 mm frame draws ≤75 W on 85-260 VAC with upper/lower pressure protection. Spares cover high-flow pump heads, pressure sensors, and tubing.
- Flow up to 300 mL/min, pressure 15 MPa
- ±1% accuracy, 20-30 mm prep columns
- Compact 240×140×330 mm, ≤75 W power
- 85-260 VAC input, pressure limit guard
Automated fraction collector Collector V1 (0.1-10 mL/min)
Collector V1 combines XYZ 3-axis motion and a PEEK wetted path for 0.1-10 mL/min collection (splitting required above 10 mL/min). Dimensions are 560×430×460 mm, 20 kg, 220 V / 200 W with CAN/RS232 and 24-bit dual-channel ADC. Spares cover purge valves, PEEK needles, racks, and ADC boards.
- 0.1-10 mL/min flow, PEEK wetted path
- XYZ 3-axis drive, 560×430×460 mm, 20 kg
- CAN / RS232, 24-bit dual-channel ADC
- Dual 96-well, 50 HPLC, 20 headspace racks
Post-column flow splitting and WKPrep + CAD coupling module
For non-UV analytes such as saponins, phospholipids, PEG, and surfactants, WKPrep adds a post-column splitter feeding a minor stream to the Hunan Lingfeng SparkFlux2000 CAD while directing the bulk flow to collection. Spares include flow splitters, delay coils, and 190-400 nm UV cells.
- 190-400 nm UV + optional CAD trigger
- Post-column splitter with delay tuning
- Targets saponins, lipids, PEG & APIs
- SparkFlux2000 CAD by Hunan Lingfeng
Selecting a WKPrep preparative HPLC configuration by pressure and flow
Beijing WeikeTory Instrument Co., Ltd.
manufactures four high-pressure binary-gradient preparative HPLC platforms: WKPrep-10 (42 MPa, 10 mL/min, ±0.5%, 4.6-10 mm columns), WKPrep-50 (30 MPa, 50 mL/min, ±0.5%, 10-20 mm), WKPrep-100 (20 MPa, 100 mL/min, ±1%, ~20 mm), and WKPrep-300 (15 MPa, 300 mL/min, ±1%, 20-30 mm).
Choose WKPrep-50 when resolution and impurity separation take priority, or WKPrep-100/300 for gram-scale throughput paired with the Collector V1 fraction collector (0.1-10 mL/min, PEEK flow path) and a post-column splitter above 10 mL/min.
Distinguishing Weiketory in-house systems from third-party brands
Weiketory in-house products comprise the WKPrep preparative HPLC series (10/50/100/300), the Collector V1 fraction collector, and the post-column splitter module for 190-400 nm UV plus universal CAD-triggered purification.
Other product lines featured on weiketory.com—the SparkFlux2000 CAD detector (manufactured by Hunan Lingfeng Instrument), GS-TEK GSBP GC columns (USA), STARLIMS / JQ SyncLIMS software, and pre-owned Agilent, Shimadzu, Waters, SCIEX, BD, or Rigaku analyzers—belong to third-party manufacturers rather than Weiketory own production.
Weiketory and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Weiketory and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Lutz Pumpen
- Equipment and parts for Tenoly
- Equipment and parts for Baoji Machine Tool / BOOHI
- Equipment and parts for Young Shin
Documents and sources
- About Beijing WeikeTory Instrument — own R&D vs. third-party brands
- Weiketory WKPrep-10/50/100/300 preparative HPLC specifications
- WKPrep-100 high-pressure preparative HPLC (English specification)
- Collector V1 fraction collector specifications and modes
- Lingfeng SparkFlux2000 CAD detector (Hunan Lingfeng brand)
- GS-TEK GSBP GC columns (third-party brand catalog)
- STARLIMS and JQ SyncLIMS laboratory software solutions
- Weiketory English catalog & third-party brand disclosure