Kovalus Separation Solutions (Koch Membrane Systems) filtration equipment
We supply ultrafiltration skids, membrane bioreactor modules and replacement membrane elements from Kovalus Separation Solutions, formerly Koch Membrane Systems.
PURON modules for membrane bioreactors
Submerged PURON PSH and PDH modules separate filtrate from activated sludge. PULSION modules use pulsed aeration. Replacement planning covers frame geometry, the filtrate header and air distribution.
- PURON PSH modules
- PURON PDH modules
- PULSION pulsed aeration
- Submerged configuration
PURON MP pressurized ultrafiltration modules
PURON MP modules use hollow fibers for pressurized water ultrafiltration. The housing connects the feed and filtrate lines. Replacement planning covers connections, backwash operation and the integrity check.
- PURON MP modules
- Pressurized ultrafiltration
- Hollow fiber element
- Integrity check
TARGA II cartridges for water treatment
TARGA II belongs to the manufacturer's hollow fiber water cartridge range. Cartridge selection depends on the existing housing and flow path. The replacement check covers end fittings, seals and backwash operation.
- TARGA II cartridges
- Water treatment
- Hollow fiber filtration
- Housing fit check
FLUID SYSTEMS reverse osmosis and nanofiltration
The FLUID SYSTEMS range includes reverse osmosis elements for brackish water and seawater, alongside nanofiltration elements. Selection is application-specific. Feed chemistry, permeate quality and pressure limits define the comparison.
- FLUID SYSTEMS elements
- Brackish water elements
- Seawater elements
- Nanofiltration elements
Sani-Pro sanitary spiral elements
The Sani-Pro range includes spiral ultrafiltration, nanofiltration and reverse osmosis elements. The process duty determines which grade fits a food line. Replacement assessment covers stream properties, cleaning conditions and the permeate tube connection.
- Sani-Pro elements
- Sanitary design
- UF and NF stages
- Reverse osmosis elements
SUPER-COR and FEG PLUS tubular modules
SUPER-COR multitube modules handle suspended solids in ultrafiltration duties. FEG PLUS is a separate tubular family. Selection considers circuit hydraulics, header junctions and permitted cleaning conditions.
- SUPER-COR modules
- FEG PLUS tubular elements
- Ultrafiltration duty
- Suspended solids handling
KPAK PLUS elements for electrocoat lines
KPAK PLUS potted spiral modules serve electrocoat baths. The separated permeate feeds rinsing stages in the circuit. A replacement assessment covers housing fit and how the separation duty affects bath operation.
- KPAK PLUS modules
- Electrocoat duty
- Potted spiral design
- Rinse circuit
Ceramic microfiltration and ultrafiltration modules
The ceramic range includes microfiltration and ultrafiltration modules. It suits processes with demanding chemical or thermal conditions when the selected materials are compatible. Selection covers feed properties, separation duty and seal limits.
- Ceramic membranes
- Microfiltration modules
- Ultrafiltration modules
- Chemical compatibility
Specify the membrane system
For water ultrafiltration, we specify PURON MP pressurized skids against feed composition and design capacity.
A membrane bioreactor also needs a review of the biological stage, air delivery and filtrate withdrawal. Retrofit planning accounts for tank space and frame arrangement.
Choose the separation duty
Surface water polishing generally aims to remove suspended particles before a downstream separation stage. A pressurized ultrafiltration skid can form part of the pretreatment for reverse osmosis, reducing the suspended-solids load on the spiral elements.
For process water, allocate the quality target to each stage in the treatment train. The quality expected after the complete installation cannot be used to specify an individual membrane.
Food applications start with a different question: should the valuable component report to the permeate or to the concentrate? That decision defines the separation objective, the feed concentration range and the method for sampling the product.
Include the volume held in the lines when the plant changes from production to cleaning.
Specify the surface water duty
Select representative locations for feed sampling at a water treatment plant. An average turbidity figure does not cover flood events, interruptions at the intake or plant startup. A module assessment also needs the temperature, the nature of the solids and the organic content.
Compare net output after water consumed by backwash and other internal users. Two systems can have the same peak production rate while delivering materially different daily volumes.
Check whether the building has enough storage and whether the drain system can accept the waste streams produced during cleaning. These requirements influence procurement even when the module model stays the same.
Retrofit a membrane bioreactor
A capacity increase in a membrane bioreactor involves more than installing extra membrane area. Coordinate incoming flow, biological loading, sludge wasting, aeration and filtrate withdrawal. The frame layout must leave room for lifting the modules and servicing the connections.
Treat the permeate manifold, air supply and instrumentation as one assembly when comparing retrofit options. On a plant with several trains, define the flow available with one train isolated for maintenance.
This gives a practical basis for reserve capacity and identifies the loading on the trains that remain online. Installation drawings should show the isolation points and provide a workable route for removing assemblies.
Sanitary steps for food and beverage
A food or beverage installation may handle fluids with very different viscosity and composition. Compare membrane elements on the basis of the separation duty and the changing behaviour of the batch as it concentrates.
If viscosity changes significantly, channel hydraulics, circulation and temperature become more important. The cleaning cycle needs its own assessment because the operating conditions can differ from the production stage.
Check the membrane and seal materials against the operating grade and the plant's sanitation routine. Define the sample locations and the end-of-batch criterion in the specification so that product quality can be compared consistently after replacing an element.
Design the reverse osmosis circuit
FLUID SYSTEMS selection starts with feed composition, the required permeate quality, the concentrate discharge constraints and the recovery target. Brackish and seawater elements address different feed duties. Evaluate concentration by stage, including the water that passes to downstream vessels.
Compare permeate flow and rejection using equivalent test conditions. The pressure vessel, feed pump, piping and element orientation place further constraints on the fit. On a retrofit, identify which assemblies will remain in service.
This gives the equipment supplier a clear boundary for the replacement proposal and helps determine whether any connections or instruments must be relocated.
Set the package and acceptance scope
Document the supply boundary for the skid, membrane racks, pumps, control panel, instruments, valves and pipe connections. The exact package depends on the selected configuration. Before installation, review the water connections, utilities, drain routing and access for opening housings.
Define the feed and operating conditions for the acceptance run, the method for measuring flow and filtrate quality, and the data available from the controller.
A spare-parts schedule should identify the assemblies that can halt production: seals, adapters, cartridges, membrane elements and instruments. Tie the list to the selected equipment configuration so that maintenance stock covers the actual skid.
Evaluate a retrofit using plant data
The existing layout determines which assemblies a retrofit can reuse. Check pumps at the relevant operating point. For valves and instrumentation, document the operating ranges and the sequence used to move from filtration to cleaning.
If the new unit changes concentrate flow, assess the impact on the rest of the plant. The useful output also depends on storage, drains and variability in the feed. Compare both normal operation and the case where one train is unavailable for cleaning.
This gives a better basis for comparing the capital investment and uptime of the equipment proposals.
Run a representative process test
A trial on the real feed helps evaluate performance that cannot be inferred directly from datasheets. Identify which compounds should remain in the concentrate and how stable the filtrate flow needs to be. Record the feed condition and sample timing so that later comparisons use the same basis.
For food processing, consider variation between batches. With wastewater, consider shifts, restarts and changes in production. Review the entire cycle, including cleaning and the time needed to return to service.
A short clean-water run can check hydraulics, while a representative feed is needed to assess fouling during operation.
Koch Membrane Systems and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Koch Membrane Systems and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.
Related equipment manufacturers
- Equipment and parts for Alfa Laval
- Equipment and parts for AdEdge Water Technologies
- Equipment and parts for ProMinent