HELUKABEL cables and connection components

Source HELUKABEL control, drive and industrial network cables, cable glands and connection components against your project specification.

JZ and OZ control cables

JZ and OZ cables carry power and control signals in machinery. The range includes PVC, PUR and halogen-free versions. Shielded and unshielded constructions serve different wiring layouts. Selection starts with the circuit and installation method.

  • JZ-500 and OZ-500 series
  • PVC and PUR jackets
  • Shielded constructions
  • Machine control circuits

TOPFLEX, TOPSERV and TOPGEBER drive cables

TOPFLEX covers motor connections, TOPSERV servo systems and TOPGEBER feedback circuits. These families address power and signal transmission. Electromagnetic shielding is considered together with the converter and the connection layout.

  • TOPFLEX motor cables
  • TOPSERV servo cables
  • TOPGEBER feedback cables
  • TOPSERV hybrid versions

Cables for continuous motion

Dedicated constructions address continuously moving applications. The catalogue distinguishes drag-chain, torsion and reeling duties. Bending and twisting are different loads. Cable selection must therefore follow the complete movement path and installation conditions.

  • Drag-chain constructions
  • Torsion-capable versions
  • Reeling applications
  • Power and data circuits

Industrial Ethernet and bus cables

The range includes Industrial Ethernet, PROFINET, PROFIBUS and CAN-Bus cables. Selection follows the actual network and installation method. Dedicated moving versions are available. A matching connector alone does not establish compatibility of the complete link.

  • Industrial Ethernet range
  • PROFINET constructions
  • PROFIBUS and CAN-Bus
  • Versions for moving use

Temperature-resistant cables and wires

The catalogue includes silicone, FEP, PTFE and glass-fibre constructions for temperature exposure. Multicore cables and individual wires are separate product groups. The operating range belongs to the selected article. Cross-section alone is insufficient for substitution.

  • Silicone constructions
  • FEP and PTFE insulation
  • Glass-fibre versions
  • Multicore and single wires

HELUTOP cable glands

Cable glands secure and protect cables at enclosure entries. The range includes plastic, brass and stainless steel. Dedicated versions address electromagnetic compatibility. Thread geometry and clamping range must match the enclosure and the cable jacket.

  • HELUTOP cable glands
  • Plastic and brass versions
  • Stainless steel versions
  • EMC-oriented constructions

Selecting a cable for the circuit

Select HELUKABEL cables by circuit, construction and installation method. A control connection, motor supply and feedback link are separate functions, even when they follow the same route. Start with the full existing designation or the electrical drawing.

Record conductor count, cross-section, protective conductor and shielding. A familiar family name is a starting point rather than a complete purchasing specification.

Distinguish cable supplied by length from a finished assembly. An assembly additionally needs connector details, pin assignment, orientation and a defined length reference. Where identification is incomplete, provide machine documents and photographs of both ends.

Evaluate an alternative against the actual operating conditions before accepting it as a replacement.

Control and connection cable construction

JZ and OZ families cover machine control and connection applications. The catalogue separates jacket materials and screened or unscreened constructions. Specify whether the cable stays inside a cabinet, connects fixed equipment or travels with a moving mechanism.

Identical electrical functions do not necessarily require identical mechanical constructions. Keep the complete designation in each order line.

Describe oil exposure, process fluids, chips and abrasion along the route. A property documented for one version is not a property of every cable carrying the brand. Agree any change from the drawing with the equipment owner.

Shield selection should follow the circuit and electromagnetic environment, including its termination at the enclosure entry.

Motor power, servo and feedback connections

TOPFLEX, TOPSERV and TOPGEBER identify different drive-cable directions. A machine can use several of them simultaneously. State the drive and motor identification, the purpose of each connection and the installed cable code.

A hybrid construction listed in the catalogue is not automatically interchangeable with separate power and feedback lines.

For an assembly, agree power conductors, signal pairs, jacket, connectors and shield termination as one specification. Check moving duty independently. The product family helps locate the right technical sheet but does not replace it.

Keeping each circuit distinct also prevents a purchasing list from merging incompatible cables into one generic drive-cable item.

Continuous movement and routing

The catalogue distinguishes drag-chain, torsion and reeling applications. Describe the real motion before requesting a cable. A linear axis needs its travel and routing conditions; a rotating joint needs its twisting duty; a reel needs its winding conditions.

General flexibility does not establish suitability for every dynamic load.

Consider outside diameter and cross-section together with chain filling, adjacent lines and end fixation. For a retrofit, retain the existing route drawing and mark changed conditions. This provides a consistent basis for comparing options.

Apply bending, speed and temperature limits only from the selected article documentation, without treating one product limit as a guarantee for the entire range.

Industrial networks and complete links

For Industrial Ethernet, PROFINET, PROFIBUS and CAN-Bus, identify the network and the connection segment. Conductor count and connector appearance do not describe all cable requirements. Specify shielding, jacket and installation method.

A moving network segment needs a construction intended for the relevant duty, while fixed routing is a separate case.

Finished links require agreed pin assignments and mating connector details. Define the length reference rather than estimating from machine size. Acceptance may include testing the complete assembly with tools appropriate to the network.

A cable technical sheet and a test result for a finished link serve different purposes; identify which documents belong to the supply.

Temperature-resistant constructions

The temperature-resistant range includes silicone, FEP, PTFE and glass-fibre constructions. Multicore cables and single wires are separate selection groups. Ambient heat, contact with a hot surface and movement create different requirements.

Describe the installation position, exposure duration and fixation so that the proposed construction can be assessed against its actual environment.

The selected cable limit does not automatically apply to a terminal, connector or gland. Review the complete connection. Separate mandatory electrical requirements from environmental conditions in the enquiry.

If another insulation material is acceptable, treat it as an alternative requiring its own technical sheet and approval. Similar appearance is insufficient evidence of equivalent insulation performance.

Cable glands and entry components

Select cable glands against both the jacket and the enclosure. Plastic, brass and stainless steel versions address different construction needs. Record the thread, entry geometry, clamping range and any required shield contact.

Include locknuts and sealing components where they form part of the requested assembly. Thread size and cable clamping range are different dimensions.

An EMC-oriented gland should be considered with the cable screen and the enclosure contact surface. Any special protection claim must belong to the selected article and installation. Divide the bill into cables, glands and connections while retaining their relationship to a particular line.

This makes it clear which parts must work together and what must be checked for each one.

Supply specification and incoming checks

SpareX works from an agreed bill of materials. Keep the cable family, full designation, quantity and unit distinct. For cable by length, specify whether separate cuts are acceptable. For assemblies, agree drawings and reference dimensions.

A total quantity does not establish that a single continuous length will be supplied, so continuity requirements should be stated explicitly.

At receipt, compare marking, completeness and condition with the approved version. Match accompanying documents to the actual item rather than only the manufacturer name. If the equipment is intended for another market, identify applicable project requirements before procurement.

Retaining the accepted specification supports repeat orders for maintenance and future line extensions.

HELUKABEL and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of HELUKABEL and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.