Mobrey level instruments and boiler controls

SpareX selects Mobrey instruments for tanks, pumping stations, silos and boiler systems: level switches, transmitters, controllers and replacement assemblies.

Float switches and MLT100 displacer transmitter

Horizontal magnetic switches provide pump control and level alarms. Vertical versions use floats or displacers. MLT100 turns displacer movement into a continuous HART measurement.

  • Horizontal or vertical installation
  • Magnetic switching mechanism
  • Direct or chamber mounting
  • MLT100: LVDT measurement

003 ultrasonic switches and MCU200 controllers

The 003 detects liquid without moving parts in a PPS body. Relay and solid-state versions are available. MCU201 and MCU203 use a separate ultrasonic gap sensor for sludge blankets, interfaces and contamination.

  • 003: relay or solid-state output
  • 003: 24 V AC/DC supply
  • MCU200: ultrasonic gap sensor
  • MCU200: controller and sensor cable

9700 hydrostatic level transmitters

The 9700 family includes 9710, 9720, 9780 and 9790 models. A ceramic sensor converts liquid head into a level signal. Submersible and externally mounted floodable versions serve industrial and marine tanks.

  • Level output: 4–20 mA
  • Flush ceramic sensing element
  • Cable, pole or flange mounting
  • Industrial and marine tank applications

DMSP non-contact transmitters and DMCU controllers

DMSP measures level above the liquid surface. DMSP900SH offers HART communication for wet wells and sumps. DMCU900 provides configuration and diagnostics; DMCU800 accepts analogue and thermocouple inputs.

  • DMSP: level, contents, open channel flow
  • DMSP900SH: IP68 enclosure
  • DMCU900: HART communication
  • DMCU800: relay control outputs

PLS paddles and DMS, DMT, VLS vibrating switches

PLS detects solids when material stops a rotating paddle. DMS and DMT sense damping of a vibrating fork. The VLS single rod serves free-flowing solids, including powder, grain and aggregate.

  • PLS: top or side installation
  • PLS: IP66 housing
  • DMS/DMT: vibrating fork sensor
  • VLS: single vibrating rod

VABC boiler controls and electrodes

VABC provides feed-pump control and level alarms. A modulating controller regulates feedwater. Sequencing blowdown valves purge connections and float chambers; electrodes serve Hydrastep and Hydratect systems.

  • VABC magnetic float controls
  • Modulating valves and control cards
  • Sequencing blowdown valves
  • Hydrastep / Hydratect electrodes

Choosing the measurement principle

Point level switches and continuous transmitters perform different jobs. A switch reports that material has reached a defined position; a transmitter reports a changing process value to the control system.

The selection therefore starts with the function: pump start and stop, a high or low alarm, tank inventory or feedwater regulation. Mobrey covers magnetic, ultrasonic, hydrostatic and vibrating technologies.

A shared brand name does not make instruments interchangeable across those measurement principles.

For liquids, selection considers whether the sensor touches the process, the condition of the surface and the available installation space. For bulk solids, the alternatives include a rotating paddle, a vibrating fork and a single vibrating rod.

Boiler controls form a separate application group because the measurement is linked to feedwater and protective outputs. SpareX coordinates the instrument assembly, process connection, required signal and included components against the intended duty.

This keeps the comparison tied to the application rather than the shape of the enclosure.

Magnetic float switches and displacer measurement

Horizontal magnetic float switches provide pump control and high or low level alarms on tanks and pressure vessels. Vertical instruments use float or displacer arrangements. Direct mounting and an external chamber have different installation and maintenance implications.

A replacement selection considers the sensing geometry, orientation, electrical function and connection to the process. The switch mechanism, sensing element and chamber belong to a defined assembly; they should be assessed together when comparing a complete instrument with a replacement component.

The MLT100 uses a displacer with LVDT displacement measurement and HART communication. Its continuous measurement function is different from the discrete output of a level switch.

Selection considers the available mounting space, the range of the particular model and the receiving control-system interface. For installed equipment, the comparison also refers to the documentation of the existing assembly.

A limit associated with one switch configuration cannot be applied to every float, displacer or chamber in the product family.

Contact ultrasound, non-contact measurement and hydrostatics

The 003 series is an ultrasonic point level switch with integrated electronics and a PPS body. It detects liquid at the sensor without moving components.

The MCU200 controller uses a separate ultrasonic gap sensor for duties including sludge blanket level, immiscible-liquid interfaces and contamination detection. Both approaches must be distinguished from an ultrasonic transmitter installed above the liquid surface.

The required result may be a wet or dry state, an interface condition or a continuously changing level value.

DMSP and DMSP900SH transmitters support non-contact measurement of level, contents and open channel flow. DMCU900 provides a configuration and diagnostic interface for HART ultrasonic transmitters; DMCU800 accepts analogue and thermocouple inputs.

The 9700 hydrostatic family instead measures liquid head using a ceramic sensing element. Submersible and externally mounted floodable versions are available. Selection compares the medium, mounting arrangement and receiving signal interface.

Foam or vapour above a liquid and deposits on a wetted sensor are different operating conditions, so the measurement principle remains an essential part of the specification.

Powder, grain and granular-material level

The PLS paddle rotates freely when material is absent. When product impedes the paddle, the switch changes state; rotation resumes after the material falls away. Available configurations include different paddles, extensions and top or side installation. Failsafe versions add diagnostic monitoring.

Selection considers the vessel shape, the required detection point and the product being handled. A high-level alarm and a low-level indication on the same silo may require different arrangements rather than a single repeated configuration.

DMS and DMT use damping of a vibrating fork to detect material at the sensing point. VLS uses a single vibrating rod for free-flowing solids such as powder, grain and aggregate. The geometry of the sensing element matters when considering deposits and material movement around the probe.

Process connection, supply and output function also form part of the comparison. A compact switch on a machine and a sensor mounted on a larger hopper may use a similar measurement principle while requiring different mechanical configurations.

Boiler assemblies and replacement components

VABC controls perform duties including feed-pump operation, level alarms and burner cut-out. Modulating controls regulate feedwater, while sequencing blowdown valves purge connections and the float chamber.

Hydrastep and Hydratect electrodes belong to their respective water and steam monitoring systems. An equipment package should distinguish sensing, operating control and protective outputs.

That separation helps determine whether the project needs a complete assembly or a specific replaceable component within an existing installation.

The manufacturer lists spares for direct-mounted, chamber-mounted and modulating float controls, modulating valves, control cards and sequencing blowdown valves. SpareX matches the requested component to the installed assembly and agreed specification.

A sensor and controller package requires a compatible measurement channel; a mechanical assembly also requires the appropriate body and process connection. The included components are defined before procurement.

Ordering a sensor, controller, chamber or valve separately does not imply that the remaining elements of the operating system are included.

Mobrey and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Mobrey and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.