Vanton (Vanton Pumps) Thermoplastic Pumps & Parts

Engineered thermoplastic pumps by Vanton (Vanton Pumps / Vanton Pump & Equipment Corp.) for corrosive, abrasive, and ultrapure fluids: CHEM-GARD horizontal, SUMP-GARD vertical, FLEX-I-LINER rotary, and PUMP/TANK systems.

CHEM-GARD CG / CGA Horizontal Centrifugal Pumps

CHEM-GARD horizontal centrifugal pumps handle acids, caustics, and slurries. Rated flows reach 330 m3/h and heads 122 m at up to 135 °C. CGA models meet ANSI B73.1 and ISO 2858 with armored housings. Replaceable parts include impellers, reverse-mounted seals, shafts, and bearings.

  • Flows up to 330 m3/h (1,450 gpm)
  • Heads to 122 m, up to 135 °C
  • PVC, CPVC, PP, PVDF, ECTFE
  • ANSI B73.1 / ISO 2858 (CGA)

CGV Vortex, CGM Mag-Drive & PRIME-GARD PG Pumps

CGV, CGM, and PRIME-GARD series cover slurries, sealless, and priming duties. CGV vortex units pass 75 mm solids up to 205 m3/h. CGM magnetic-drive pumps (102 m3/h) use a dual PTFE/FRP can. Spares include containment cans, magnetic couplings, vortex impellers, and PG check valves.

  • CGV: 75 mm solids, 205 m3/h
  • CGM: mag-drive, PTFE/FRP can
  • PG: self-priming up to 4.6 m
  • Interchangeable CHEM-GARD pedestals

SUMP-GARD SG / SGL Vertical Centrifugal Sump Pumps

SUMP-GARD SG and SGL vertical pumps serve sumps up to 15 m deep. All wetted parts and heavy-wall shaft sleeves are molded in PVC, CPVC, PP, or PVDF. Capacity reaches 330 m3/h and 85 m head up to 135 °C. Service parts include shaft sleeves, impellers, bearings, and columns.

  • Sump depths up to 15 m (50 ft)
  • Flows to 330 m3/h, 85 m head
  • Heavy-wall PVC/CPVC/PP/PVDF sleeve
  • SGL segmented column for low headroom

SGK Cantilevered, SGV Vortex & SGW Semiconductor Pumps

SGK, SGV, and SGW cover dry-run, slurry, and ultrapure semiconductor duties. Bearingless cantilevered SGK pumps run dry up to 227 m3/h at 2 m length. Compact SGW (50 m3/h) fits OEM skids, while SGV passes 75 mm solids. Replaceable parts include sleeves, impellers, and strainers.

  • SGK: dry-run cantilevered, 227 m3/h
  • SGV: recessed impeller, 75 mm solids
  • SGW: 50 m3/h, compact 0.56 m length
  • NEMA / IEC and C-face motor mounts

FLEX-I-LINER XB / CC Sealless Rotary Peristaltic Pumps

FLEX-I-LINER XB and CC rotary pumps are sealless and self-priming up to 1,300 cSt. Fluid touches only the plastic body block and flexible elastomer liner. Flows span 1.26 lpm to 9 m3/h at 310 kPa and 121 °C. Key spares are elastomer liners, body blocks, rotors, and bearings.

  • Flows 1.26 lpm to 9 m3/h (40 gpm)
  • Pressures to 310 kPa, up to 121 °C
  • Body blocks: PP, UHMW PE, PTFE
  • Liners: Viton, Hypalon, Nordel, NR

PUMP/TANK Integrated Non-Metallic Pump & Tank Systems

PUMP/TANK non-metallic stations pair tanks up to 19 m3 with Vanton thermoplastic pumps. Builds include double-wall leak detection and automated PLC pH neutralization skids. Motor areas use Fume-Gard vapor seals. Replaceable items include Flex-Plug valves, level sensors, and gaskets.

  • Tank capacities up to 19 m3 (5,000 gal)
  • Double-wall tanks with leak sensors
  • PLC-controlled pH neutralization skids
  • Fume-Gard seals & Flex-Plug valves

Thermoplastic Material Ratings & Serial-Number Traceability

Vanton engineers wetted parts by fluid chemistry, temperature, and abrasion (Taber 1,000-cycle loss): PVC up to 60 °C (12–20 mg), PP up to 85 °C (15–20 mg), PE up to 93 °C (5 mg), CPVC up to 99 °C (20 mg), PVDF up to 135 °C (5–10 mg), ECTFE up to 149 °C (5–10 mg), and PTFE up to 260 °C. FLEX-I-LINER pumps pair PP, UHMW PE, or PTFE body blocks with Natural Rubber, Neoprene, Buna-N, Hypalon, Viton, or Nordel liners.

CHEM-GARD horizontal pumps use a sliding front bearing pedestal and reverse-mounted seal arrangement so metal never contacts process liquid, while SUMP-GARD vertical pumps isolate the steel shaft inside a heavy-wall thermoplastic sleeve.

Every Vanton pump is factory-tested for hydrostatic tightness, hydraulic curve, vibration, noise, and power draw, with permanent serial-number records for rapid spare-parts matching.

Vanton and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of Vanton and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Related equipment manufacturers

Documents and sources

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

WeChat QR code: Nastia

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code: @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.@ananasprosto в Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.