X-RAY WorX Open Microfocus X-ray Tubes and Inspection Sources
Technical specifications and engineering selection of open microfocus X-ray tubes CT Plus, transmission tubes THE Plus, submicron series TCNF, and rod anodes RAC by X-RAY WorX.
X-RAY WorX CT Plus High Power Microfocus X-ray Tubes
Open microfocus X-ray tubes of the CT Plus series by X-RAY WorX combine up to 320 kV acceleration voltage with 500 W emission power for high-density computed tomography. The reflection target design inspects dense automotive structural parts and aerospace alloy assemblies.
- Configurations XWT-225-CT Plus, XWT-240-CT Plus, XWT-300 and 320 kV
- Focal spot dimension from 6 to 500 microns at 500 W emission power
- Reflection target setup with dedicated chiller cooling on the head
- Plug-in filament cathodes, vacuum O-ring gaskets, turbopump assemblies
X-RAY WorX THE Plus High Resolution Microfocus Tubes
High resolution microfocus X-ray tubes of the THE Plus series by X-RAY WorX feature diamond-based transmission targets with defect resolution from 2 to 30 microns at up to 80 W target power. They are tailored for CT inspection of semiconductors, printed boards, and EV batteries.
- Tubes XWT-160-THE Plus, XWT-190-THE Plus, XWT-225-THE, and 240-THE Plus
- Spatial resolution down to 2 microns with target power up to 80 Watts
- Transmission target architecture built on synthetic diamond window
- Click-in filament cathodes, collimators, diamond targets, vacuum seals
X-RAY WorX TCNF Plus Submicron Resolution X-ray Tubes
Submicron resolution tubes of the TCNF Plus series by X-RAY WorX incorporate electron optics with condenser lenses and internal cooling systems. The design achieves JIMA defect resolution down to 0.5 microns for nanoscopic inspection of silicon chips, bonding wires, and advanced materials.
- Tube models XWT-160-TCNF Plus, XWT-190-TCNF Plus, and XWT-225-TCNF Plus
- Submicron spatial resolution down to 0.5 microns on JIMA test masks
- Electron optical column with condenser lens and internal head cooling
- Precision cathode filaments, beam aperture stops, nano diamond targets
X-RAY WorX RAC Microfocus Rod Anode X-ray Tubes
Rod anode X-ray tubes of the RA and RAC series by X-RAY WorX feature tube probes up to 150 cm length and diameters down to 8 mm with panoramic targets. They enable high-resolution radiography of circumferential pipe and aircraft heat exchanger welds.
- Series XWT-160-RA, XWT-225-RA, XWT-225-RAC, and RAC Superfocus models
- Slender rod anode tube probes up to 1500 mm length with 8 mm diameter
- Interchangeable 360-degree panoramic and directional beam target heads
- Modular rod anodes, target exchange tips, internal vacuum fluoro-seals
X-RAY WorX XC Dual Head Microfocus X-ray Tubes
Dual head microfocus tubes of the XC series by X-RAY WorX combine transmission and reflection target heads on a single vacuum chamber. Operators switch seamlessly between submicron 2D imaging and high-penetration 3D CT inspection without breaking tube vacuum.
- Dual-head configurations XWT-225-XC and XWT-240-XC for inspection cells
- Dual emission geometries integrating transmission and reflection targets
- Electromagnetic electron beam deflection switching inside chamber body
- Dual cathode filaments, paired target sets, vacuum isolation valves
X-RAY WorX Click-in Cathodes and Target Assemblies
Factory calibrated click-in cathode modules and tungsten target plates on copper and diamond backings by X-RAY WorX maintain stable emission. The components restore nominal electron beam geometry in open microfocus tubes without prolonged system downtime.
- Pre-aligned click-in cathode assemblies for quick filament replacement
- Tungsten, molybdenum, and diamond transmission target substrates
- Fluoropolymer vacuum O-rings, flanges, and coolant fluid inline filters
- Turbomolecular vacuum pumps, high voltage sockets, connection cables
Anode Structure and Chiller Integration in CT Plus High Power Tubes
German manufacturer X-RAY WorX designs high-power open microfocus X-ray tubes of the CT Plus series with reflection targets for industrial computed tomography of massive metal housings, structural welds, and aerospace composite assemblies.
Operating at acceleration voltages up to 320 kV with beam emission powers reaching 500 Watts, the focal spot heat dissipation requires sophisticated thermal management. CT Plus tubes incorporate closed-loop liquid cooling across the tube head and turbomolecular pump mounting flange.
The integrated Automatic Intensity Control system continuously balances emission current drift, ensuring exceptional beam output stability during multi-hour high-resolution volumetric scans.
Synthetic Diamond Transmission Targets and Precision Optics in THE Plus
High-resolution microfocus X-ray tubes of the THE Plus series by X-RAY WorX employ transmission geometry engineered on synthetic diamond windows coated with pure tungsten films.
The outstanding thermal conductivity of diamond spreads high energy densities rapidly, supporting target powers up to 80 Watts while preserving focal spots down to submicron levels.
Coupled with multi-pole electromagnetic electron beam focusing coils, the design resolves fine features down to 2 microns on standard JIMA inspection charts. These capabilities are indispensable for non-destructive inspection of BGA micro-bumps, wire bonds, and multilayer battery cells.
Panoramic Radiography and Internal Cooling of RAC Rod Anode Probes
Specialized rod anode microfocus tubes of the RA and RAC series manufactured by X-RAY WorX deliver panoramic non-destructive examination of circumferential welds inside narrow tubular structures, aerospace engines, and shell-and-tube exchangers.
The slender rod anode probe measuring down to 8 mm outer diameter and extending up to 1500 mm in length inserts directly into tubular components.
The source projects an isotropic 360-degree beam geometry, exposing the entire weld circumference onto digital detector arrays in single exposures compliant with EN ISO 17636-2.
RAC Superfocus variants feature internal coolant circulation directly to the target tip to prevent focal drift during continuous duty cycles.
High Vacuum Architectures, Turbomolecular Pumping, and Isolation Valves
The open demountable design of X-RAY WorX tubes relies on maintaining oil-free high vacuum levels around 10^-5 mbar inside the optical column to ensure unimpeded electron flight without residual gas scattering.
A compact turbomolecular drag pump equipped with ceramic hybrid bearings mounts directly to the tube body, supported by an oil-free forevacuum backing unit. An automated electromagnetic venting valve isolates the vacuum chamber during power outages or standby states.
Low outgassing fluorocarbon O-rings preserve electrode integrity, while dedicated thermal switches monitor turbopump temperature continuously.
X-RAY WorX and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of X-RAY WorX and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.