ChartWater equipment selection

Technical selection and equipment supply for ChartWater: SDOX oxygenation units, CDOX pH neutralization, modular WaterPOD plants, advanced media, and VSi-CO2 storage vessels engineered to project specifications.

SDOX® oxygen dissolution

ChartWater describes SDOX as dissolved oxygen technology for wastewater biological treatment, post-treatment aeration, and odor control. State the installed configuration and sidestream arrangement when requesting a unit or replacement component.

  • Biological wastewater treatment
  • Post-treatment aeration
  • Odor and corrosion control
  • Selection by installed configuration

CDOX® carbon dioxide pH control

The manufacturer describes CDOX as a carbon dioxide based pH control system. Its water treatment applications include remineralization and replacing strong acids in appropriate processes. Water chemistry and the required operating window determine the project specification.

  • Carbon dioxide dissolution
  • Process pH control
  • Remineralization applications
  • Selection using water chemistry and flow

PFAS treatment options

ChartWater lists four PFAS treatment approaches. Selection between adsorption, ion exchange, and membrane treatment depends on source water quality, the target compounds, and the project requirements. Identify the installed process before specifying replacement media or modules.

  • Granular activated carbon GAC
  • Ion exchange IX
  • FLUORO-SORB media
  • Flow reversal reverse osmosis FR-RO

WaterPOD™ containerized treatment

AdEdge describes WaterPOD as an integrated containerized water treatment package. WP-20 and WP-40 enclosures accommodate project-specific processes. The treatment train, number of modules, and enclosure options must be established for the destination site.

  • WP-20 and WP-40 enclosures
  • Pre-engineered treatment integration
  • Configurations for different contaminants
  • Insulation and HVAC options by project

VSi-CO2 vertical storage systems

Chart describes VSi-CO2 as integrated outdoor carbon dioxide storage and supply equipment. Models 6, 14, 30, and 50 Ton share a listed MAWP of 24.1 bar. Model names must be distinguished from the usable metric carbon dioxide capacity.

  • Models 6, 14, 30, and 50 Ton
  • Listed MAWP 24.1 bar
  • Net CO2 capacity 6.0 to 41.1 metric tonnes
  • Composite Super Insulation™ vacuum system

biottta® biological water treatment

AdEdge documents biottta as a dual-stage fixed-bed process developed for groundwater drinking water treatment. The plant combines an anoxic bioreactor and an aerobic biofilter. Nitrate treatment is among the documented applications; the process is specified against actual water analysis.

  • Dual-stage fixed-bed treatment
  • Anoxic bioreactor
  • Aerobic biofilter
  • biottta 8, 10, and 12 models

Bayoxide® E33 arsenic adsorption media

AdEdge identifies Bayoxide E33 as a crystalline granular iron oxide used in arsenic adsorption applications. The material is produced, shipped, and loaded dry. A replacement enquiry should identify the vessel, current media, and relevant water chemistry.

  • Crystalline iron oxide material
  • Granular adsorption media
  • Dry product handling
  • Selection by vessel and water chemistry

HV-TURBO aeration compressors

ChartWater includes Howden equipment in its aeration portfolio. The HV-TURBO brochure separately illustrates a large unit at 40000–80000 Nm³/h and 0.4–1.5 bar differential pressure. These figures describe that example rather than the entire compressor range.

  • Large unit 40000–80000 Nm³/h
  • That example uses 0.4–1.5 bar differential pressure
  • IGV, VDV, or Dual Point Control™ options
  • Selection by model and operating point

ChartWater scope and equipment identity

ChartWater brings together water treatment solutions associated with AdEdge, BlueInGreen, Chart cryogenic equipment, and Howden aeration equipment. The July 31, 2025 legal merger announcement concerns AdEdge and BlueInGreen.

A technology name, an equipment manufacturer, and the legal company name therefore serve different purposes when identifying an installed system.

Separate gas dissolution, packaged water treatment, filtration media, carbon dioxide storage, and aeration compressors in the enquiry. A brochure for one item does not establish the specification of another.

Identify both the existing treatment process and the requested scope, whether this is one replacement component or equipment for a new process section. Include the nameplate rather than relying only on the facility name.

Information needed for a replacement part

Provide a clear equipment nameplate, an overall photograph, and the markings of the component being replaced. If a parts list is available, identify the relevant line and its position on the assembly drawing.

Preserve model suffixes, serial numbers, and revision identifiers because similar looking components can have different connections or electrical arrangements.

State the quantity, reason for replacement, and the requested assembly boundary. A valve enquiry benefits from connection size, service medium, and documented operating conditions. An instrument requires its measurement range, supply, and signal details.

These are observations about the installed item, not universal specifications for the brand. The responsible site specialist should assess installation suitability against the equipment documentation.

Defining an SDOX or CDOX project

For a new process, provide water flow, water chemistry, temperature, treatment objectives, and available gas supply. Distinguish oxygen delivery from carbon dioxide pH control because they require different process information.

For an existing system, add the installed module designation, its connection arrangement, and the specific items requiring replacement or investigation.

Record measured conditions together with the operating state in which they were observed. A dissolved oxygen value or a pH reading alone does not establish the required treatment duty. For an upgrade, describe the desired change separately from the current result.

Equipment selection supports the specification process; it does not replace the project design or the safety assessment for work on an operating plant.

Preparing a PFAS treatment specification

List the compounds identified by laboratory analysis and retain their measurement units. Include other water quality parameters, flow, operating schedule, and site space. ChartWater documents GAC, ion exchange, FLUORO-SORB, and FR-RO as different treatment approaches.

A project enquiry should make clear whether it concerns a new process or replacement items in an installed treatment train.

For existing adsorption vessels, identify the media, vessel dimensions, number of units, and available operating history. For a membrane section, supply the installed module designations and stage arrangement. State required outlet targets separately from current measured performance.

This gives each proposal a common basis for evaluation and prevents a result from another installation being mistaken for a prediction for the source water at your site.

Establishing the WaterPOD package boundary

WaterPOD identifies a containerized treatment arrangement rather than a single fixed list of internal equipment. The brochure describes project configurations and enclosure options.

Before selecting a package, define the contaminants, treatment flow, climate, access route, and connection points for water and electrical services. Clarify which site works are included in the project.

For a module already in operation, provide the internal equipment list and photographs of the relevant pumps, valves, control cabinets, and piping. Container length alone cannot identify a replacement pump or controller.

For a new system, document the interface between the delivered module and the site installation. Agree the treatment scope and enclosure configuration explicitly so that transport, utility planning, and receiving inspections can follow the same equipment schedule.

Reading the VSi-CO2 capacity table

The Chart table distinguishes model designation, gross and net capacity, Ton and Tonne units, maximum allowable working pressure, and physical dimensions. Use the net metric carbon dioxide capacity where the project requires usable mass.

The number in a model designation is not a direct statement of usable capacity in metric tonnes.

For replacement items on an installed vessel, provide the vessel documentation and the component tag on its diagram. The brochure lists pressure and level instruments, valves, and regulators, but the actual assembly must be checked against its configuration.

Do not transfer carbon dioxide service parameters to oxygen equipment or another gas. Material compatibility, safety settings, and return to service depend on the specific system documentation and the responsible site engineering assessment.

Specifying adsorption media or biological treatment

For Bayoxide E33 or another treatment material, identify the existing product, quantity in the latest schedule, and filter vessel details. Add raw and treated water analysis, flow, and observed pressure difference.

This helps distinguish a request for the same material from a proposal to change the treatment process. Record the operating conditions associated with the measurements.

Plan the replacement quantity, removal arrangements, and handling of used material with the responsible site personnel. A product name does not establish a universal media replacement interval.

For biottta, also provide the model, stage arrangement, operating schedule, and a list of required components. Biological treatment and adsorption media replacement represent different process tasks and need separate technical information even if they appear in one procurement enquiry.

Selecting aeration compressor equipment

Provide the HV-TURBO nameplate, compressor designation, and drive details. For a new machine, state the required flow together with reference conditions, differential pressure, control requirement, and inlet environment.

Normal and actual cubic metres cannot be compared without a common reference basis. Supply the plant duty or operating profile rather than a nominal flow value alone.

For a replacement component, include its position on the assembly drawing and the installed markings. The brochure describes different control arrangements: IGV, VDV, and Dual Point Control depend on configuration.

The large unit example at 40000–80000 Nm³/h is not the specification of every compressor. The operating point, drive, and connections must be matched to the actual machine rather than inferred from a similar casing or a portfolio photograph.

Enquiry, quotation, and delivery planning

Use the page form to send the model, quantity, photographs, and a technical specification. A new equipment enquiry should define the required process outcome; a parts enquiry should identify the component and installed machine.

If several systems are involved, separate the requested items into a clear equipment schedule with quantities and units. Keep drawing references consistent across attachments.

The quotation preparation period depends on the completeness of the input and the complexity of the package; the expected response timing is agreed after the enquiry is reviewed. Compare item designations, quantities, and package boundaries against the submitted schedule.

For equipment delivery planning, identify the destination, receiving constraints, utility interfaces, and the party responsible for each site connection. Keep acceptance criteria attached to the selected configuration.

Receiving equipment and keeping its identity

Before delivery, establish who will receive the equipment and which agreed schedule will be used to check the shipment. A large module may require an access route, unloading arrangements, and a prepared placement area.

Individual parts benefit from packaging labels that link each item to the correct equipment position.

On receipt, compare the markings and quantities with the agreed schedule and record packaging condition and visible damage. Use the item documentation for storage and installation preparation. Dry media, electronic instruments, and gas service components require different handling procedures.

Record the installation date and the replacement designation in the equipment history so that a later enquiry can identify what is actually fitted.

Related manufacturers

ChartWater and model names are trademarks of their respective owners and are used only to identify the equipment for which we source parts. SpareX is not an official dealer, distributor or representative of ChartWater and is not affiliated with the trademark owner. Origin, documents and warranty are stated for each item in the quotation.

Official manufacturer sources and documentation

Industrial equipment

Request a quote

Describe your requirements and attach up to 5 files, each up to 20 MB.

You can also drag photos or documents here.

You can also email us. Opening your email app does not send an enquiry automatically.

WeChat · Nastia

English-speaking contact

Nastia — scan this QR code to add her on WeChat

Scan the QR code to add Nastia on WeChat.

Save QR image

On this phone: save the image, then choose it from your photos in WeChat’s scanner.

Telegram · Nastia

Contact Nastia

Telegram QR code for @ananasprosto

Scan the QR code or open @ananasprosto in Telegram.

Save QR image

Scan the QR code or open @ananasprosto in Telegram.